Near-Infrared Spectroscopy for the In-Line Characterization of Powder Voiding Part II: Quantification of Enhanced Flow Properties of Surface Modified Active Pharmaceutical Ingredients

被引:0
作者
Lauren Beach
Jorge Ropero
Ajit Mujumdar
Manel Alcalà
Rodolfo J. Romañach
Rajesh N. Davé
机构
[1] New Jersey Institute of Technology,Department of Chemical, Biological and Pharmaceutical Engineering
[2] University of Puerto Rico,Department of Chemistry
[3] Universitat Autònoma de Barcelona,Grup de Quimiometria Aplicada, Departament de Química (U. Analítica), Facultat de Ciències
来源
Journal of Pharmaceutical Innovation | 2010年 / 5卷
关键词
Dry-particle coating; Flow improvement of APIs; Flow uniformity; Near-infrared spectroscopy; Angle of repose; Flow additives; Surface modification; Nano silica;
D O I
暂无
中图分类号
学科分类号
摘要
In this work, dry-particle coating was used to modify the surface properties of active pharmaceutical ingredients (APIs) having extremely poor flow properties. Near-infrared (NIR) spectroscopy was utilized as a novel approach to characterize the improved flow behavior of APIs and their blends. Acetaminophen and ibuprofen were coated with nano-sized silica at two different coating levels (0.5% and 1% w/w of the API) in dry-particle coating devices viz. magnetically assisted impaction coater (MAIC) and Hybridizer. Surface modified (dry coated) APIs were then blended with excipient (spray dried lactose monohydrate) in a V-blender. As a baseline comparison to dry coating, the silica addition was also accomplished by two commonly used industry methods, i.e., passing a portion of API with silica through a sieve (sieve blending method) or blending a portion of API powder with silica in a V-blender (preblending method). Flow results showed that dry particle coated acetaminophen as well as ibuprofen blends performed significantly better than uncoated API blends at higher API concentrations. In addition, examination of the flow intensity from NIR spectra (inverse signal to noise ratio of spectra) and its standard deviation revealed that dry particle coated blends showed better uniformity of flow as compared to the other methods. Angle of repose measurements corroborated these results, showing that the majority of the blends prepared from coated APIs stayed in either passable or fair category.
引用
收藏
页码:1 / 13
页数:12
相关论文
共 97 条
[1]  
Thalberg K(2004)Comparison of different flowability tests for powders for inhalation Powder Technol 146 206-13
[2]  
Lindholm D(2004)Flowability measurements of pharmaceutical powder mixtures with poor flow using five different techniques Drug Dev Ind Pharm 30 785-91
[3]  
Axelsson A(1995)The effect of particle size and shape on the surface specific dissolution rate of micronized practically insoluble drugs Int J Pharm 122 35-47
[4]  
Lindberg N(1897)The rate of solution of solid substances in their own solutions J Am Chem Soc 19 930-75
[5]  
Mosharraf M(2002)Poor aqueous solubility—an industry wide problem in drug discovery America Pharmaceutical Review 53 82-86
[6]  
Nyström C(1995)Particle size reduction for improvement of oral bioavailability of hydrophobic drugs: absolute oral bioavailability of nanocrystalline Danzol in beagle dogs Int J Pharm 125 91-49
[7]  
Noyes AA(1978)Effect of interparticle cohesive forces on the flow behavior of powders Powder Technol 20 161-67
[8]  
Whitney WR(1990)Function and mechanism of flow conditioners under various loading pressure conditions in bulk powders Powder Technol 63 81-48
[9]  
Lipinkski CA(1998)The influence of fines on the flowability of alumina powders in test hoppers Powder Handl Proc 10 147-97
[10]  
Liversidge GG(2001)Synthesis of engineered particulates with tailored properties using dry particle coating Powder Technol 117 40-33