Metallurgical Investigation of Buried Ductile Cast Iron Sewerage System Pipeline Premature Failure

被引:0
作者
S. Fida Hassan
机构
[1] King Fahd University of Petroleum and Minerals,
来源
Journal of Failure Analysis and Prevention | 2023年 / 23卷
关键词
Ductile cast iron; Sewerage piping; Erosion–corrosion; Corrosion fatigue; Failure;
D O I
暂无
中图分类号
学科分类号
摘要
Premature failure of two upward-inclined underground pipes carrying sewage caused sinkhole formation in a busy urban road. Metallurgical failure analysis revealed that the pipes were made of ductile cast iron. External and internal coatings were appropriate to protect the pipes from external soil and internal sewage slurry corrosion. Partial filling of sewage slurry during the pumping recess allowed turbulent flow in the empty section during pumping, and the impact of turbulence eroded the internal coating, i.e., mortar lining, introduced erosion–corrosion and progressively reduced the pipe wall thickness in the upper half of the pipes resulting to weakening. Intermittent turbulence led to some localized corrosion fatigue-induced fracture in the weakened pipe wall. Erosion–corrosion with the assistance of corrosion fatigue led to the premature failure of the ductile cast iron pipes.
引用
收藏
页码:2542 / 2553
页数:11
相关论文
共 71 条
  • [1] Rajani B(2003)Protecting ductile-iron water mains: what protection method works best for what soil condition? J. Am. Water Works Assoc. 95 110-125
  • [2] Kleiner Y(2021)Effect of the austenitizing temperature on microstructure evolution and impact toughness of a novel bainite ductile iron Met. Mater. Int. 27 4014-4022
  • [3] Wang Y(2008)Weibull-based methodology for condition assessment of cast iron water mains and its application Fatigue Fract. Eng. Mater. Struct. 31 370-385
  • [4] Zhang Y(2018)Factors influencing corrosion of metal pipes in soils Environ. Chem. Lett. 16 861-879
  • [5] Song R(2016)On the residual strength of aging cast iron trunk mains: physically-based models for asset failure Mater. Sci. Eng. A 663 204-212
  • [6] Huang L(2023)Failure analysis in buried ductile iron pipelines: a study of leakage in drinking water distribution systems Eng. Fail. Anal. 151 107361-506
  • [7] Pei Y(2010)Hydrogen induced premature failure of massive cast medium carbon steel anchor fluke Mater. Des. 31 956-2185
  • [8] Belmonte HMS(2010)Cement particle induced failure of cold potable water copper plumbing Eng. Fail. Anal. 10 393-11
  • [9] Mulheron M(2010)Failure analysis of gearbox and clutch shaft from a marine engine J. Fail. Anal. Prev. 24 496-136
  • [10] Smith PA(2018)Failure analysis of pitted copper pipes used in underground water and preventive measures Met. Mater. Int. 71 2175-380