Design and experimental testing of an electro-thermal microgripper for cell manipulation

被引:0
作者
Aurelio Somà
Sonia Iamoni
Rodica Voicu
Raluca Müller
Muaiyd H. M. Al-Zandi
Changhai Wang
机构
[1] Politecnico di Torino,Department of Mechanical and Aerospace Engineering
[2] National Institute for Research and Development in Micro Technologies-IMT,Institute of Sensors
[3] Signals and Systems School of Engineering and Physical Sciences Heriot-Watt University,undefined
来源
Microsystem Technologies | 2018年 / 24卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the design, fabrication and experimental characterization of an electro-thermally actuated microgripper suitable for single-cell manipulation. The analysis of the mechanical properties of cells is of great interest both in medicine and biology because the study of the cellular mechanical behaviour and resistance is necessary in these fields. Microgrippers (Bio-MEMS) have an important role in the manipulation of biological tissues and cells. In recent works, the research group simulated the mechanical behavior of grippers and the different actuation strategies. Considering the dimensional specifications and targets imposed by actuation and biocompatibility, in this paper, a microgripper based on electro-thermal actuation is studied. Starting from previous numerical results, a novel SU8 structure is designed and realized according to the micro-fabrication constraints and then the structure is simulated using the finite element method (FEM)-based thermo-structural simulations in ANSYS. Therefore, the fabrication method and steps are presented and the gripper has been developed and tested. Finally, the tip displacements of the gripper, electro-thermally actuated in different operating conditions, are compared with those obtained by means of numerical FEM simulations. A good agreement is obtained between simulations and experimental results.
引用
收藏
页码:1053 / 1060
页数:7
相关论文
共 112 条
  • [1] Al-Zandi M(2017)Measurement and characterisation of displacement and temperature of polymer based electrothermal microgrippers Microsyst Technol 85 1128-1130
  • [2] Wang C(2008)Electrothermal microgrippers for pick-and-place operations Microelectron Eng 16 7-15
  • [3] Voicu R(2007)Monolithically fabricated microgripper with integrated force sensor for manipulating micro-objects and biological cells aligned in an ultrasonic field J Microelectromech Syst 21 7-9
  • [4] Muller R(2012)A compact manually actuated micromanipulator J Microelectromech Syst 14 4188-4196
  • [5] Andersen KN(2014)On-demand weighing of single dry biological particles over a 5-order-of-magnitude dynamic range Lab Chip 125 438-445
  • [6] Carlson K(2006)Design, fabrication, and testing of a 3-DOF HARM micromanipulator on (111) silicon substrate Sens Actuators A 158 320-327
  • [7] Petersen DH(2010)A hybrid-type electrostatically driven microgripper with an integrated vacuum tool Sens Actuators A 4 50536-50541
  • [8] Mølhave K(2014)A microgripper sensor device capable of detecting ion efflux from whole cells RSC Adv 32 148-152
  • [9] Eichhorn V(2010)Characterization of an electro-thermal micro gripper and tip sharpening using FIB technique Microsyst Technol 23 11-19
  • [10] Fatikow S(2008)Development of a microgripping system for handling of microcomponents Precis Eng 20 869-877