The NAC proton treatment planning system

被引:0
作者
Andries N. Schreuder
Dan T. L. Jones
Julyan E. Symons
Evan A. De Kock
Jan K. Hough
Jenny Wilson
Fred J. A. Vernimmen
Wolfgang Schlegel
Angelika Höss
Michael Lee
机构
[1] National Accelerator Centre,Department of Radiation Oncology
[2] Groote Schuur Hospital,Department of Medical Physics
[3] Tygerberg Hospital,undefined
[4] Deutsches Krebsforschungszentrum,undefined
[5] Institute of Cancer Research and Royal Marsden Hospital,undefined
[6] Clatterbridge Centre for Oncology,undefined
来源
Strahlentherapie und Onkologie | 1999年 / 175卷
关键词
Proton therapy; Dose calculation; Treatment planning; Rayline-tracing;
D O I
暂无
中图分类号
学科分类号
摘要
A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.
引用
收藏
页码:10 / 12
页数:2
相关论文
共 25 条
[1]  
Bennett KF(1994)Patient positioning for proton therapy at the National Accelerator Centre S Afr J Sci 90 370-1
[2]  
Rüther H(1993)Dreidimensionale Bestralungsplanung. Untersuchungen zur klinischen Integration Strahlenther Onkol 169 159-67
[3]  
Van der Vlugt G(1993)Fractionated stereotactically guided radiotherapy of head and neck tumors: a report on clinical use of a new system in 195 cases Radiother Oncol 29 203-13
[4]  
Gademan G(1994)A comparison of proton and megavoltage X-ray treatment planning for prostate cancer Radiother Oncol 33 239-53
[5]  
Schlegel W(1993)An empirical method to build up a model of proton dose distribution for a radiotherapy treatment-planning package Phys Med Biol 38 989-98
[6]  
Bürkelbach J(1992)Differential-pencil-beam dose calculations for charged particles Med Phys 19 137-49
[7]  
Gademan G(1996)The calibration of CT Hounsfield units for radiotherapy treatment planning Phys Med Biol 41 111-24
[8]  
Schlegel W(1986)Degradation of the Bragg peak due to inhomogeneities Phys Med Biol 31 1-15
[9]  
Debus J(1986)Proton beam penumbra: Effects of separation between patient and beam modifying devices Med Phys 13 734-41
[10]  
Lee M(undefined)undefined undefined undefined undefined-undefined