Experimental Investigation and Thermoacoustic Analysis of a Single-Stage Pulse Tube Refrigerator with an Active Displacer

被引:0
作者
Kongkuai Ying
Zhenhua Jiang
Wang Yin
Jiantang Song
Shaoshuai Liu
Haifeng Zhu
Nanxi Li
Yinong Wu
机构
[1] Shanghai Institute of Technical Physics,
[2] University of Chinese Academy of Sciences,undefined
[3] Nantong Zilang Science and Technology City,undefined
来源
Journal of Low Temperature Physics | 2023年 / 210卷
关键词
Active displacer; Thermoacoustic; Stirling-type; Space application; Pulse tube refrigerator;
D O I
暂无
中图分类号
学科分类号
摘要
The Stirling-type pulse tube refrigerator is a widely used refrigerator that has been extensively applied in space. An optimal phase angle between the pressure wave and volume flow is essential for a pulse tube refrigerator. The active displacer installed at the hot end of a pulse tube can be used to actively control the phase angle and enable recovery of the expansion power at the warm end of the pulse tube, leading to high efficiency. The main parameters for a pulse tube refrigerator with an active displacer are the phase and displacement of the active displacer. This manuscript studies the impact of displacer phase and displacement on a 40 K single-stage pulse tube refrigerator with an active displacer by thermoacoustic analysis, which is helpful for studying the thermodynamic characteristics of such a refrigerator and provides a method for more effective design and computing. The effects on the pressure, acoustic power, and cooling capacity are investigated by analytically solving the thermoacoustic model. A pulse tube refrigerator developed in our laboratory is tested, and the experimental results are compared with the results of thermoacoustic analysis.
引用
收藏
页码:514 / 535
页数:21
相关论文
共 67 条
[1]  
Ju YCW(1998)Dynamic experimental study of the multi-bypass pulse tube refrigerator with two-bypass tubes J. Therm. Sci. 7 61-66
[2]  
Yuan Z(2015)Development of a high-frequency coaxial multi-bypass pulse tube refrigerator below 14K Cryogenics 67 28-30
[3]  
Zhou Q(1990)Double inlet pulse tube refrigerators: an important improvement Cryogenics 30 514-520
[4]  
Chen L(2010)Single-stage high frequency coaxial pulse tube cryocooler with base temperature below 30K Cryogenics 50 342-346
[5]  
Zhu X(2018)Study on a high frequency pulse tube cryocooler capable of achieving temperatures below 4 K by helium-4 Cryogenics 94 103-109
[6]  
Zhu S(2017)Experimental investigation of pulse tube refrigerator with displacer Int. J. Refrig. 76 1-6
[7]  
Wu P(2020)Coaxial Stirling pulse tube cryocooler with active displacer Cryogenics 111 103143-253
[8]  
Chen Z(2021)On-orbit performance of the FY-4 GIIRS stirling cryocooler over 2 years J. Low Temp. Phys. 203 244-762
[9]  
Yang LW(2001)Experimental analysis of free warm expander pulse tube Cryogenics 41 757-755
[10]  
Xun YQ(2001)Numerical model of free warm expander pulse tube cooler Cryogenics 41 751-390