Deep Learning-based Inaccuracy Compensation in Reconstruction of High Resolution XCT Data

被引:0
作者
Emre Topal
Markus Löffler
Ehrenfried Zschech
机构
[1] Technische Universität Dresden,
[2] Dresden Center for Nanoanalysis,undefined
[3] Fraunhofer IKTS,undefined
[4] Institute for Ceramic Technologies and Systems,undefined
来源
Scientific Reports | / 10卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
While X-ray computed tomography (XCT) is pushed further into the micro- and nanoscale, the limitations of various tool components and object motion become more apparent. For high-resolution XCT, it is necessary but practically difficult to align these tool components with sub-micron precision. The aim is to develop a novel reconstruction methodology that considers unavoidable misalignment and object motion during the data acquisition in order to obtain high-quality three-dimensional images and that is applicable for data recovery from incomplete datasets. A reconstruction software empowered by sophisticated correction modules that autonomously estimates and compensates artefacts using gradient descent and deep learning algorithms has been developed and applied. For motion estimation, a novel computer vision methodology coupled with a deep convolutional neural network approach provides estimates for the object motion by tracking features throughout the adjacent projections. The model is trained using the forward projections of simulated phantoms that consist of several simple geometrical features such as sphere, triangle and rectangular. The feature maps extracted by a neural network are used to detect and to classify features done by a support vector machine. For missing data recovery, a novel deep convolutional neural network is used to infer high-quality reconstruction data from incomplete sets of projections. The forward and back projections of simulated geometric shapes from a range of angular ranges are used to train the model. The model is able to learn the angular dependency based on a limited angle coverage and to propose a new set of projections to suppress artefacts. High-quality three-dimensional images demonstrate that it is possible to effectively suppress artefacts caused by thermomechanical instability of tool components and objects resulting in motion, by center of rotation misalignment and by inaccuracy in the detector position without additional computational efforts. Data recovery from incomplete sets of projections result in directly corrected projections instead of suppressing artefacts in the final reconstructed images. The proposed methodology has been proven and is demonstrated for a ball bearing sample. The reconstruction results are compared to prior corrections and benchmarked with a commercially available reconstruction software. Compared to conventional approaches in XCT imaging and data analysis, the proposed methodology for the generation of high-quality three-dimensional X-ray images is fully autonomous. The methodology presented here has been proven for high-resolution micro-XCT and nano-XCT, however, is applicable for all length scales.
引用
收藏
相关论文
共 85 条
[1]  
Maire E(2014)Quantitative X-ray tomography International Materials Reviews 59 1-43
[2]  
Withers PJ(2018)Laboratory Computed X-Ray Tomography – A Nondestructive Technique for 3D Microstructure Analyis of Materials: The working group “X-Ray Tomography” is headed by Prof. Dr. Ehrenfried Zschech Practical Metallography 55 539-555
[3]  
Zschech E(2017)Visualization of the internal structure of Didymosphenia geminata frustules using nano X-ray tomography Sci Rep 7 1143-1151
[4]  
Zgłobicka I(2013) Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation Experimental Mechanics 53 19-22
[5]  
Brault R(2013)Exploring electrochemical devices using X-ray microscopy: 3D micro-structure of batteries and fuel cells Microsc. Anal 27 293-299
[6]  
Shearing PR(2018)A novel micro-double cantilever beam (micro-DCB) test in an X-ray microscope to study crack propagation in materials and structures Materials Today Communications 16 578-579
[7]  
Kutukova K(2013)Electron and X-ray Tomography of Iron/Iron Oxide Redox Reactions for Large-Scale Hydrogen Storage Microscopy and Microanalysis 19 898-906
[8]  
Niese S(2006)Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography IEEE Transactions on Medical Imaging 25 061902-3833
[9]  
Gelb J(2014)Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment: Fiducial marker-based correction for involuntary motion Medical Physics 41 3825-1284
[10]  