Blood flow in the human ascending aorta: a combined MRI and CFD study

被引:0
作者
Armin Leuprecht
Sebastian Kozerke
Peter Boesiger
Karl Perktold
机构
[1] Graz University of Technology,Institute of Mathematics
[2] University of Zurich and Swiss Federal Institute of Technology Zurich,Institute of Biomedical Engineering
来源
Journal of Engineering Mathematics | 2003年 / 47卷
关键词
arbitrary Lagrangian-eulerian method; artificial valve; finite element method; realistic modeling; wall shear stress;
D O I
暂无
中图分类号
学科分类号
摘要
Blood flow through the ascending aorta of two individuals is studied numerically. Realistic flow simulation is enabled by the combination of MRI and CFD. The aim of this study is the validation of the calculated flow field and, on the other hand, a comparison between flow distal to an artificial heart valve and native flow of a healthy volunteer. Three-dimensional, time-dependent computer models of the human ascending aorta were reconstructed from three-directional data sets acquired by MRI in the subjects studied. MRI velocity measurements downstream of the aortic valve provided the inflow conditions for the computational study. The pulsatile flow is described by the ALE-modified Navier-Stokes equations with respect to the time-varying flow domain. The numerical approach applies our own developed finite-element solver. During systolic acceleration the flow patterns distal to the valves do not show major differences between the two configurations. During flow deceleration, however, a significant influence of the disturbed inflow conditions can be found in the whole segment. Using the methods proposed, simulation of blood flow in the ascending aorta of the two subjects could be successfully performed. There was good qualitative agreement of blood velocities predicted by CFD and velocity data measured by MRI. In conclusion, the approach described herein might offer a new way towards an improved assessment of detailed in vivo flow conditions and alterations of blood flow associated with heart valve prostheses in particular. Combining CFD and MRI potentially extends the quantification of hemodynamic variables in vivo at a scale beyond the resolution limit inherent to MRI.
引用
收藏
页码:387 / 404
页数:17
相关论文
共 78 条
[1]  
Chandran K.B.(1993)Flow dynamics in the human aorta J. Biomech. Engng. 115 611-616
[2]  
Friedman M.H.(1983)Geometric risk factors for arteriosclerosis Arteriosclerosis 4 85-94
[3]  
Berger S.A.(1983)Flow in curved tubes Ann. Rev. Fluid Mech. 15 461-512
[4]  
Talbot L.(2002)Computational fluid dynamics modeling and analysis of the 3-d distortion of the human aortic arch Comput. Meth. Biomech. Biomed. Engng. 5 249-260
[5]  
Yao L.S.(2002)Combined CFD and MRI study of blood flow in a human ascending aorta model Biorheology 39 425-429
[6]  
Mori D.(1998)Combined MRI and CFD analysis of fully developed steady and pulsatile laminar flow through a bend J. Magn. Reson. Imag. 8 1158-1171
[7]  
Yamaguchi T.(1999)Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging Ann. Biomed. Engng. 27 32-41
[8]  
Leuprecht A.(2000)Numerical study of blood in an anatomically realistic aorto-iliac bifurcation generated from MRI data Magn. Reson. Med. 43 565-576
[9]  
Perktold K.(2002)Validation of the coupling of magnetic resonance imaging velocity measurements with computational fluid dynamics in a U bend Artificial Organs 26 622-635
[10]  
Kozerke S.(1985)In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses Life Support Syst. 3 283-312