Adaptation of the Bath Ankylosing Spondylitis Functional Index to the Turkish population, its reliability and validity: functional assessment in AS

被引:0
作者
Burcu Yanık
Yeşim Kurtaiş Gürsel
Şehim Kutlay
Saime Ay
Atilla Halil Elhan
机构
[1] Ankara University,Department of Physical Medicine and Rehabilitation, School of Medicine
[2] Ankara University,Department of Biostatistics, School of Medicine
来源
Clinical Rheumatology | 2005年 / 24卷
关键词
Adaptation; Ankylosing spondylitis; Functional index; Reliability; Validity;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to adapt the Bath Ankylosing Spondylitis Functional Index (BASFI) to the Turkish population and investigate the reliability and the validity of the Turkish version. Seventy-six patients with ankylosing spondylitis (AS) were included in the study. The functional status of the patients was assessed by using the adapted Turkish version of the BASFI twice, at recruitment and 24 h later. For validity analysis, patients were also assessed by the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) evaluating disease activity, the Bath Ankylosing Spondylitis Global Score (BAS-G) indicating effect of the disease on patient’s well-being, physician’s assessment of the disease activity and pain intensity. Spinal mobility was assessed by the Bath Ankylosing Spondylitis Metrology Index (BASMI). Erythrocyte sedimentation rate (ESR) and serum C-reactive protein (CRP) levels of the patients were also recorded. The lumbar region and the sacroiliac joints were assessed by Stoke Ankylosing Spondylitis Spine Score (SASSS) and the hip joints were assessed by Bath Ankylosing Spondylitis Radiology Index hip (BASRI-h). The internal consistency was 0.89 (Cronbach’s alpha), which showed a high reliability for the Turkish version of the BASFI. Test-retest reliability was good, with a high intraclass correlation coefficient between the two time points (ICC=0.93). Significant correlations were detected between the BASFI and the BASDAI, BAS-G, doctor’s global assessment, and general pain intensity (r=0.62, p<0.001; r=0.47, p<0.001; r=0.55, p<0.001; r=0.47, p<0.001, respectively). The adaptation of the BASFI to the Turkish population was successful and it was found to be reliable and valid among Turkish patients. Thus, studies using the Turkish BASFI can be compared with international studies.
引用
收藏
页码:41 / 47
页数:6
相关论文
共 25 条
  • [1] Calin H(1994)The Swedish version of the Bath ankylosing spondylitis functional index. Reliability and validity J Rheumatol 21 184-9
  • [2] Cronstedt A(1999)undefined Scand J Rheumatol 111 1-undefined
  • [3] Waldner CH(2000)undefined J Rheumatol 27 1251-undefined
  • [4] Stenstrom undefined(1997)undefined J Rheumatol 24 2225-undefined
  • [5] Heikkila undefined(1994)undefined J Rheumatol 21 2281-undefined
  • [6] van undefined(1998)undefined J Rheumatol 15 302-undefined
  • [7] Calin undefined(1990)undefined J Rheumatol 17 946-undefined
  • [8] Dougados undefined(1994)undefined Br J Rheumatol 33 1060-undefined
  • [9] Daltroy undefined(1999)undefined J Rheumatol 26 1959-undefined
  • [10] Abbott undefined(2001)undefined Rheumatol Int 20 211-undefined