Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction

被引:0
作者
Hideki Yano
Shigeo Horinaka
Manami Watahik
Tomoko Watanabe
Toshihiko Ishimitsu
机构
[1] Dokkyo Medical University Hospital,Department of Cardiology and Nephrology
[2] Nasu Red Cross Hospital,Department of Cardiology
来源
Heart and Vessels | 2019年 / 34卷
关键词
Everolimus-eluting stent; Optical coherence tomography; ST-elevation myocardial infarction; Neointimal thickness; Apposition; Stent strut coverage;
D O I
暂无
中图分类号
学科分类号
摘要
Cobalt–chromium everolimus-eluting stent (CoCr EES) is associated with a lower rate of stent thrombosis even in patients with ST-elevation myocardial infarction (STEMI). However, the time-serial changes of endothelial coverage of the stent struts in the extremely early period have never been reported, especially in patients with STEMI. The aim of this study was to compare the vessel healing process between CoCr EES and cobalt–chromium bare metal stent (CoCr BMS) implantations using optical coherence tomography (OCT) in patients with STEMI. Sixty-three patients who had primary emergent percutaneous coronary intervention (PCI) with CoCr EES (42 patients) or CoCr BMS (21 patients) were enrolled in this study for 3 years. OCT was performed just after, 2 and 12 weeks after EES or BMS implantations. Time-serial changes in the neointimal coverage (NIC), the neointimal thickness, and malapposition of stent struts were evaluated. NIC of stent struts did not differ between CoCr EES (23.2%, 99.4%) and CoCr BMS (24.0%, 97.8%) at 2 weeks and 12 weeks after PCI, respectively. Thicknesses of the neointima on the stent strut was significantly thinner in CoCr EES (34.0 ± 13.8, 107.0 ± 32.4 µm) than in CoCr BMS (40.0 ± 14.6, 115.7 ± 33.8 µm) at 2 weeks and 12 weeks after PCI (p = 0.011, p = 0.008), respectively. The malapposition did not differ just after PCI, and was completely resolved at 12 weeks after PCI in both groups. Thrombus was significantly less in CoCr EES than in CoCr BMS at 2 weeks (19.0% vs 42.9%, p < 0.01), and decreased over time in both groups, but at 12 weeks, disappeared only in CoCr EES (CoCr EES: 0% vs. CoCr BMS: 4.8%, p = 0.56). This study demonstrated that NIC and apposition of the stent struts almost completed at 12 weeks after EES and BMS implantations, while the neointimal thickness on the stent struts were thinner in EES than in BMS. Moreover, thrombus was significantly less in EES than in BMS implantations 2 weeks after PCI, which may explain the lower rate of acute and subacute stent thrombosis of EES compared with BMS.
引用
收藏
页码:572 / 582
页数:10
相关论文
共 533 条
  • [21] Sabaté M(2009)Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach Heart 95 1913-1919
  • [22] Suttorp MJ(2012)Optical coherence tomography: from research to practice Eur Heart J Cardiovasc Imaging 13 370-384
  • [23] Kelbaek H(2010)Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: optical coherence tomographic analysis JACC Cardiovasc Interv 3 1074-1079
  • [24] Spaulding C(2008)Endothelial cell recovery between comparator polymer-based drug-eluting stents J Am Coll Cardiol 52 333-342
  • [25] Menichelli M(2010)Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography Circ Cardiovasc Interv 3 476-483
  • [26] Vermeersch P(2009)Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography Circ J 73 1033-1037
  • [27] Dirksen MT(2017)Early vascular responses after everolimus-eluting stent implantation assessed by serial observations of intracoronary optical coherence tomography Heart Vessels 32 804-812
  • [28] Cervinka P(2006)Assessment of coronary arterial thrombus by optical coherence tomography Am J Cardiol 97 1713-1717
  • [29] Petronio AS(2007)Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition EuroIntervention 3 128-136
  • [30] Nordmann AJ(2009)The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography Int J Cardiol 134 180-188