Automatic segmentation of blood vessels in retinal images using 2D Gabor wavelet and sub-image thresholding resulting from image partition

被引:0
作者
da Silva Amorim L. [1 ]
Ferreira F.M.F. [1 ]
Guimarães J.R. [2 ]
Peixoto Z.M.A. [1 ]
机构
[1] Graduation Program in Electrical Engineering, Pontifical Catholic University of Minas Gerais - PUC-MG, Belo Horizonte, Itau Avenue, 525, Dom Cabral, Belo Horizonte, CEP 30535-012, MG
[2] Dr. Ricardo Guimarães Eye Hospital, Belo Horizonte, MG
关键词
2D Gabor wavelet; Denoising; Image partitioning; Image thresholding; Low contrast; Segmentation of retinal vessels;
D O I
10.1007/s42600-019-00028-9
中图分类号
学科分类号
摘要
Purpose: The retina features the only blood vessel network in humans that is visible in a non-invasive imaging method. This, along with uniqueness and stability throughout life in healthy subjects, makes it an ideal target for personal identification methods in biometric systems and also for the screening and diagnosis of diseases. However, retinal images usually present low contrast of the vessels in relation to the retinal background and high level of noise stemming mainly from the acquisition process. This work aims to reduce noise and improve contrast to increase the accuracy of retinal vessel segmentation. Methods: 2D Gabor wavelet (GW) is usually employed to reduce noise and improve vessel contrast in relation to the background. In this work, it is proposed that, before the thresholding, the GW output images are partitioned into 20 sub-images in such a way that each can be treated independently. Results: The images used were obtained from two public databases, DRIVE and STARE, and the algorithm was developed in MatLab® environment. The proposed approach reached an accuracy of 96.15%, sensitivity of 73.42%, and specificity of 98.30% in DRIVE. In STARE, the accuracy was 94.87%, sensitivity 71.74%, and specificity 96.93%. Conclusion: The methods proposed by the authors indicate gains in accuracy and specificity in the automatic detection of retinal vessels, in both databases used, when compared with those in the main published works. The accuracy is also higher than the 94.73% in interobserver accuracy previously determined as the gold standard. © 2019, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:241 / 249
页数:8
相关论文
共 35 条
[1]  
Abramoff M.D., Garvin M.K., Sonka M., Retinal imaging and image analysis, IEEE Rev Biomed Eng, 3, pp. 169-208, (2010)
[2]  
Akram M.U., Tariq A., Nasir S., Khan A.S., Gabor wavelet based vessel segmentation in retinal images, IEEE symposium on computational intelligence for image processing
[3]  
2009 Mar 30 - Apr 2
[4]  
Nashville, United States of America, pp. 116-119, (2009)
[5]  
Akram M.U., Tariq A., Khan A.S., Retinal recognition: personal identification using blood vessels, International conference for internet technology and secured transactions
[6]  
2011 Dec 11–14
[7]  
Abu Dhabi, United Arab Emirates, pp. 180-184, (2011)
[8]  
Ali A., Hussain A., Wan Zaki W.M.D., Vessel extraction in retinal images using automatic thresholding and Gabor wavelet, 39th Annual international conference of the IEEE engineering in medicine and biology society (EMBC)
[9]  
2017 Jul 11–15
[10]  
Seogwipo, South Korea, pp. 365-368, (2017)