Purpose: This study aimed to develop a digital manometer capable of measuring the maximal respiratory pressures at functional residual capacity level—pulmonary volume where the pressures related to the elastic recoil of the respiratory system are minimized—and to validate its functionally in healthy individuals. Methods: The proposed device was built based on three main components: the hardware, electronic part; the firmware, computational part; and the mechanics, composed of the device housing, connections, and filters used. Also, the software was updated to allow measurements at functional residual capacity. Functional validation was performed with 30 healthy individuals (15 men), aged between 20 and 40 years. The intraclass correlation coefficient (ICC) verified concurrent validity and test-retest reliability reproducibility, and pressures at functional residual capacity were compared to pressures at residual volume and total lung pulmonary capacity, by paired t test. Results: The developed device met the desired functional and non-functional requirements. The volume calculated from the acquired flow values showed variability of less than 2%. There was total agreement between the expected and obtained pressures. Regarding functional validation, an ICC ≥ 0.84; p < 0.001 was observed for both concurrent validity and test-retest reliability. Measurements at functional residual capacity were significantly lower than measurements performed at residual volume and total lung capacity (p < 0.05). Conclusion: The TrueForce can be considered a valid and reliable instrument for measures of maximum respiratory pressures performed in the functional residual capacity, and it can be used in clinical trial research. © 2021, Sociedade Brasileira de Engenharia Biomedica.
引用
收藏
页码:181 / 191
页数:10
相关论文
共 50 条
  • [31] A METHOD OF ESTIMATING THE FUNCTIONAL RESIDUAL CAPACITY OF INFANTS WITH RESPIRATORY-DISTRESS SYNDROME
    RICHARDSON, P
    WYMAN, M
    JUNG, AL
    CRITICAL CARE MEDICINE, 1980, 8 (11) : 667 - 670
  • [32] IMPORTANCE OF RESPIRATORY MUSCLE TONIC ACTIVITY IN THE MAINTENANCE OF THE FUNCTIONAL RESIDUAL CAPACITY (FRC)
    MULLER, N
    BRYAN, AC
    LAM, A
    KNILL, R
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 1382 - 1382
  • [33] RESPIRATORY VOLUME TIMING RELATIONSHIP DURING SUSTAINED ELEVATION OF FUNCTIONAL RESIDUAL CAPACITY
    MUZA, SR
    LEE, LY
    PAN, CP
    ZECHMAN, FW
    FRAZIER, DT
    RESPIRATION PHYSIOLOGY, 1984, 58 (01): : 77 - 86
  • [34] RESPIRATORY STUDIES IN CHILDREN .2. FUNCTIONAL RESIDUAL CAPACITY IN HEALTHY CHILDREN
    GEUBELLE, F
    DERUDDER, P
    ACTA PAEDIATRICA, 1961, 50 (03) : 277 - &
  • [35] PERIODIC CHANGES IN FUNCTIONAL RESIDUAL CAPACITY AND OTHER RESPIRATORY VARIABLES IN RESTING MAN
    HLASTALA, MP
    WRANNE, B
    LENFANT, CJ
    ACTA PHYSIOLOGICA SCANDINAVICA, 1973, : 74 - 74
  • [36] Functional residual capacity in beagle dogs with and without acute respiratory distress syndrome
    Liu, Qi
    Gao, Yong-Hua
    Hua, Dong-Ming
    Li, Wen
    Cheng, Zhe
    Zheng, Hui
    Chen, Rong-Chang
    JOURNAL OF THORACIC DISEASE, 2015, 7 (08) : 1459 - 1466
  • [37] ABSENCE OF DENSITY DEPENDENCE OF MAXIMAL EXPIRATORY FLOWS AT FUNCTIONAL RESIDUAL, CAPACITY IN INFANTS WITH BRONCHOPULMONARY DYSPLASIA
    TEPPER, RS
    PEDIATRIC RESEARCH, 1987, 21 (04) : A506 - A506
  • [38] FUNCTIONAL RESIDUAL CAPACITY (FRC) AND MAXIMAL FLOW AT FRC (VMAXFRC) IN HEALTHY PRESCHOOL-CHILDREN
    WALL, MA
    MISLEY, MC
    DICKERSON, D
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (04): : 223 - 223
  • [39] Maximal Flow at Functional Residual Capacity in Healthy Children From Birth to 7 Years, and Beyond
    Vilozni, Daphna
    Bentur, Lea
    Godfrey, Simon
    Barker, Michael
    Bar-Yishay, Ephraim
    CHEST, 2011, 139 (06) : 1439 - 1444
  • [40] Influence of a heat and moisture exchanger with a microbiological filter on measurements of maximal respiratory pressures and vital capacity in patients with COPD
    Jaber Lucato, Jeanette Janaina
    Claudino Barbosa, Renata Cleia
    de Almeida Picanco, Patricia Salerno
    Nogueira da Cunha, Thiago Marraccini
    Righetti, Renato Fraga
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2020, 46 (01)