Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study

被引:0
|
作者
Sonali Kumar
David Molony
Sameer Khawaja
Kaylyn Crawford
Elizabeth W. Thompson
Olivia Hung
Imran Shah
Jessica Navas-Simbana
Arlen Ho
Arnav Kumar
Yi-An Ko
Hossein Hosseini
Adrien Lefieux
Joo Myung Lee
Joo-Yong Hahn
Shao-Liang Chen
Hiromasa Otake
Takashi Akasaka
Eun-Seok Shin
Bon-Kwon Koo
Goran Stankovic
Dejan Milasinovic
Chang-Wook Nam
Ki-Bum Won
Javier Escaned
Andrejs Erglis
Yoshinobu Murasato
Alessandro Veneziani
Habib Samady
机构
[1] Emory University School of Medicine,Division of Cardiology, Department of Medicine
[2] Georgia Heart Institute,Department of Mathematics and Computer Science
[3] Northeast Georgia Health System,Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute
[4] Emory University,Nanjing First Hospital
[5] Samsung Medical Center,Division of Cardiovascular Medicine, Department of Internal Medicine
[6] Sungkyunkwan University School of Medicine,Department of Cardiovascular Medicine
[7] Nanjing Medical University,Department of Cardiology
[8] Kobe University Graduate School of Medicine,Department of Internal Medicine and Cardiovascular Center
[9] Wakayama Medical University,Department of Cardiology
[10] Ulsan Medical Center,Department of Medicine, Dongsan Medical Center
[11] Seoul National University Hospital,Department of Cardiology
[12] University Clinical Center of Serbia,Pauls Stradins Clinical University Hospital
[13] Keimyung University,Department of Cardiology and Clinical Research Center
[14] Hospital Clínico San Carlos Madrid,undefined
[15] University of Latvia,undefined
[16] National Hospital Organization Kyushu Medical Center,undefined
来源
The International Journal of Cardiovascular Imaging | 2023年 / 39卷
关键词
Intravascular ultrasound; Underexpansion; Wall shear stress; Percutaneous coronary intervention;
D O I
暂无
中图分类号
学科分类号
摘要
Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63±11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7°±14.7°. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233–3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.
引用
收藏
页码:1375 / 1382
页数:7
相关论文
共 50 条
  • [31] Endothelial cell distributions and migration under conditions of flow shear stress around a stent wire
    Anzai, Hitomi
    Watanabe, Tomohito
    Han, Xiaobo
    Putra, Narendra Kurnia
    Wang, Zi
    Kobayashi, Hisatoshi
    Ohta, Makoto
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (04) : 345 - 354
  • [32] Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress
    Chen, Henry Y.
    Sinha, Anjan K.
    Choy, Jenny S.
    Zheng, Hai
    Sturek, Michael
    Bigelow, Brian
    Bhatt, Deepak L.
    Kassab, Ghassan S.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 301 (06): : H2254 - H2263
  • [33] Multidirectional wall shear stress promotes advanced coronary plaque development: comparing five shear stress metrics
    Hoogendoorn, Ayla
    Kok, Annette M.
    Hartman, Eline M. J.
    de Nisco, Giuseppe
    Casadonte, Lorena
    Chiastra, Claudio
    Coenen, Adriaan
    Korteland, Suze-Anne
    Van der Heiden, Kim
    Gijsen, Frank J. H.
    Duncker, Dirk J.
    van der Steen, Antonius F. W.
    Wentzel, Jolanda J.
    CARDIOVASCULAR RESEARCH, 2020, 116 (06) : 1136 - 1146
  • [34] AN INSTRUMENT FOR WALL SHEAR STRESS MEASUREMENT
    Yan, Yuchao
    Jiang, Chengyu
    Ma, Binghe
    Chen, Runbo
    Deng, Jinjun
    Luo, Jian
    Gao, Tiande
    Xu, Hui
    NINTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2019, 11343
  • [35] Experimental and numerical study of pulsatile flows through stenosis: Wall shear stress analysis
    Deplano, V
    Siouffi, M
    JOURNAL OF BIOMECHANICS, 1999, 32 (10) : 1081 - 1090
  • [36] High wall shear stress and high-risk plaque: an emerging concept
    Parham Eshtehardi
    Adam J. Brown
    Ankit Bhargava
    Charis Costopoulos
    Olivia Y. Hung
    Michel T. Corban
    Hossein Hosseini
    Bill D. Gogas
    Don P. Giddens
    Habib Samady
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1089 - 1099
  • [37] Y-Stent Coiling of Basilar Bifurcation Aneurysms Induces a Dynamic Angular Vascular Remodeling With Alteration of the Apical Wall Shear Stress Pattern
    Gao, Bulang
    Baharoglu, Merih I.
    Cohen, Alex D.
    Malek, Adel M.
    NEUROSURGERY, 2013, 72 (04) : 617 - 628
  • [38] High Wall Shear Stress can Predict Wall Degradation in Ascending Aortic Aneurysms: An Integrated Biomechanics Study
    Salmasi, M. Yousuf
    Pirola, Selene
    Sasidharan, Sumesh
    Fisichella, Serena M.
    Redaelli, Alberto
    Jarral, Omar A.
    O'Regan, Declan P.
    Oo, Aung Ye
    Moore, James E., Jr.
    Xu, Xiao Yun
    Athanasiou, Thanos
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9 (09):
  • [39] A MEMS surface fence for wall shear stress measurement with high sensitivity
    Bing He Ma
    Cheng Yu Ma
    Microsystem Technologies, 2016, 22 : 239 - 246
  • [40] Transient wall shear stress measurements and estimates at high Reynolds numbers
    Sundstrom, L. R. Joel
    Cervantes, Michel J.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 58 : 112 - 119