Determination of antibiotic susceptibility of bacteria by flow cytometric method

被引:0
作者
Huseyin Hatipoglu
Gulay Erman
Hande Toptan
Mehmet Koroglu
Mustafa Altindis
机构
[1] Sakarya University,Department of Medical Microbiology, Faculty of Medicine
[2] Sakarya University,Health Services Education Research and Application Centre
[3] Sakarya Training and Research Hospital,Medical Microbiology Laboratory
来源
World Journal of Microbiology and Biotechnology | 2022年 / 38卷
关键词
Antibiotic; Antibiotic resistance; Antibiotic susceptibility; Antibiotic susceptibility test methods; Bacteria; Flow cytometric method;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, it was aimed to determine the antibiotic susceptibility of bacterial strains by using flow cytometry method by comparing them with current standardized methods. Eleven clinical isolates and 6 standard bacterial strains were included in the study. MIC values were determined by broth microdilution method (BMD), VITEK 2® automated system and flow cytometric method (FCM). FCM was performed with the Accuri C6 flow cytometer. For all strains except P. aeuruginosa ATCC 27853 [BMD-FCM:r = 0.557(p = 0.048); VITEK 2-FCM:r = 0.529(p = 0.063)], E. faecalis ATCC 29212 [BMD-FCM:r = 0.393(p = 0.295); BMD-VITEK 2:r = 0.393(p = 0.295)], and vancomycin-resistant E. faecium clinical isolate [BMD-FCM:r = 0.452(p = 0.063)] r values were in the range of 0.802–0.969 for BMD-FCM (p < 0.001), 0.655–0.941 for BMD-VITEK 2 (p < 0.005) and 0.667–0.953 for FCM-VITEK 2 (p < 0.005). Correlation values of antibiotic susceptibility test results between three methods for Gram-negative bacteria were found as follows; r = 0.927(p < 0.001) for BMD-FCM, r = 0.851(p < 0.001) for BMD-VITEK 2, r = 0.807(p < 0.001) for VITEK 2-FCM. Correlation values were found as follows for Gram positive bacteria; r = 0.848(p < 0.001) for BMD-FCM, r = 0.877(p < 0.001) for BMD-VITEK 2, r = 0.800(p < 0.001) for VITEK 2-FCM. When all bacteria included in the study were evaluated as a total; it was r = 0.911(p < 0.001) for BMD-FCM, r = 0.888(p < 0.001) for BMD-VITEK 2, r = 0.835(p < 0.001) for VITEK 2-FCM. The methicillin resistance of the clinical methicillin resistant S. aureus isolate could not be detected by FCM. It was determined that there was a high level of correlation between methods. FCM shortens the duration of antibiotic susceptibility tests by 12–14 h and gives results within the same day. However, it has not been standardized to be widely used in microbiology laboratories and experienced personnel are needed for its implementation.
引用
收藏
相关论文
共 154 条
  • [11] Pinho E(2013)Very rapid flow cytometric assessment of antimicrobial susceptibility during the apparent lag phase of microbial (re)growth Lancet Infect Dis 13 1057-2966
  • [12] Mergulhão P(2002)Rapid identification of J Clin Microbiol 40 1681-1798
  • [13] Silva-Dias A(2001) by matrix-assisted laser desorption/ionization-time of flight mass spectrometry and detection of meropenem resistance by flow cytometric assay J Clin Microbiol 39 2964-4283
  • [14] Marques N(2017)Antibiotic resistance-the need for global solutions Sci Rep 7 1903-3826
  • [15] Martins-Oliveira I(2011)Evaluation of the VITEK 2 system for identification and antimicrobial susceptibility testing of medically relevant gram-positive cocci Emerg Infect Dis 17 1791-undefined
  • [16] Rodrigues AG(2013)Evaluation of VITEK 2 rapid identification and susceptibility testing system against gram-negative clinical isolates Bacteriol Parasitol 7 1259-undefined
  • [17] Paiva JA(2016)Rapid susceptibility profiling of carbapenem-resistant Front Microbiol 51 4281-undefined
  • [18] Cantón R(2013)Global spread of carbapenemase-producing Enterobacteriaceae J Clin Microbiol 3 83-undefined
  • [19] Pina-Vaz C(2018)Detection, identification and susceptibility testing of bacteria by flow cytometry Arch Clin Microbiol 84 e37-undefined
  • [20] Falagas ME(2018)A flow cytometric and computational approaches to carbapenems affinity to the different types of carbapenemases Curr Protoc Cytomet 7 1121-undefined