The potential of surgical strategy for incomplete stent apposition after implantation of a sirolimus eluting stent

被引:0
作者
Nagai T. [1 ]
Shibata M. [1 ]
Suzuki S. [2 ]
Matsubara T. [1 ]
机构
[1] Department of Cardiology, Hiratsuka City Hospital, Hiratsuka, Kanagawa 254-0065
[2] Department of Cardiovascular Surgery, Hiratsuka City Hospital, Kanagawa
关键词
Coronary artery bypass grafting; Incomplete stent apposition; Sirolimus eluting stent; Very late stent thrombosis;
D O I
10.1007/s12928-010-0047-7
中图分类号
学科分类号
摘要
Sirolimus-eluting stents (SES) had been implanted in the left anterior descending artery of a 77-year-old male. Three years later, he was admitted for ST elevation myocardial infarction caused by stent thrombosis accompanied with incomplete stent apposition (ISA), and balloon angioplasty had to be performed on him. However, 6 months later, he was admitted for angina. There was progression of ISA and severe stenosis. Considering the allergic reaction to the polymer of the SES, or the risk of future stent thrombosis, coronary artery bypass grafting was selected for the revascularization. One year after the procedure, he felt no symptoms and the bypass graft was patent. A surgical strategy may be considered for recurrence of coronary events accompanied with ISA after stent implantation. © 2010 Japanese Association of Cardiovascular Intervention and Therapeutics.
引用
收藏
页码:157 / 161
页数:4
相关论文
共 17 条
[1]  
Ujiie Y., Hirosaka A., Mitsugi M., Ohwada T., Igarashi M., Kijima M., Komatsu N., Hisa S., Abe Y., Tsuda T., Et al., Effects of angiotensin-converting enzyme inhibitors or an angiotensin receptor blocker in combination with aspirin and cilostazol on in-stent restenosis, Int Heart J, 47, 2, pp. 173-184, (2006)
[2]  
Moses J.W., Leon M.B., Popma J.J., Fitzgerald P.J., Holmes D.R., O'Shaughnessy C., Caputo R.P., Kereiakes D.J., Williams D.O., Teirstein P.S., Et al., Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery, N Engl J Med, 349, 14, pp. 1315-1323, (2003)
[3]  
Stone G.W., Ellis S.G., Cox D.A., Hermiller J., O'Shaughnessy C., Mann J.T., Turco M., Caputo R., Bergin P., Greenberg J., Et al., A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease, N Engl J Med, 350, 3, pp. 221-231, (2004)
[4]  
Virmani R., Guagliumi G., Farb A., Musumeci G., Grieco N., Motta T., Mihalcsik L., Tespili M., Valsecchi O., Kolodgie F.D., Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?, Circulation, 109, 6, pp. 701-705, (2004)
[5]  
McFadden E.P., Stabile E., Regar E., Cheneau E., Ong A.T., Kinnaird T., Suddath W.O., Weissman N.J., Torguson R., Kent K.M., Et al., Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy, Lancet, 364, 9444, pp. 1519-1521, (2004)
[6]  
Lee C.H., Lim J., Low A., Tan H.C., Lim Y.T., Late angiographic stent thrombosis of polymer based paclitaxel eluting stent, Heart, 92, 4, pp. 551-553, (2006)
[7]  
Ishikawa T., Mori C., Abe Y., Aramaki K., Takeda H., Tanaka Y., Sugiura T., Yagi H., Seo A., Shibata T., Et al., A case report of late coronary stent thrombosis manifested as acute myocardial infarction 19 months after stenting, Jpn Heart J, 45, 1, pp. 147-152, (2004)
[8]  
Cook S., Ladich E., Nakazawa G., Eshtehardi P., Neidhart M., Vogel R., Togni M., Wenaweser P., Billinger M., Seiler C., Et al., Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis, Circulation, 120, 5, pp. 391-399, (2009)
[9]  
Mintz G.S., Weissman N.J., Fitzgerald P.J., Intravascular ultrasound assessment of the mechanisms and results of brachytherapy, Circulation, 104, 11, pp. 1320-1325, (2001)
[10]  
Kozuma K., Costa M.A., Sabate M., Serrano P., van der Giessen W.J., Ligthart J.M., Coen V.L., Levendag P.C., Serruys P.W., Late stent malposition occurring after intracoronary beta-irradiation detected by intravascular ultrasound, J Invasive Cardiol, 11, 10, pp. 651-655, (1999)