Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation

被引:0
作者
Wen Luo
Xiaodong Zhou
Xue Tian
Xialong Ren
Minjuan Zheng
Kejun Gu
Guangbin He
机构
[1] Fourth Military Medical University,Department of Ultrasound Xijing Hospital
[2] A & S Science Technology Development Co,undefined
[3] Ltd,undefined
来源
Advances in Therapy | 2006年 / 23卷
关键词
high-intensity focused ultrasound; ultrasound; contrast agent; therapeutic efficiency; coagulation;
D O I
暂无
中图分类号
学科分类号
摘要
High-intensity focused ultrasound (HIFU) is becoming an increasingly attractive modality for ablation. Enhancement of HIFU is an important issue that has been discussed and investigated worldwide. Ultrasound contrast agents are considered to constitute an efficient medium for changing acoustic characteristics and improving energy deposition in the focal region. The role of microbubbles in inducing enhanced heating, cavitation, and other related events in HIFU ablation has been investigated, with the goal of improving coagulation necrosis volume or decreasing acoustic power and exposure duration. Consequently, with the use of ultrasound contrast agents, applications of HIFU are expected to become more efficient, safe, and accurate and to produce fewer adverse effects. This paper reviews studies that have been conducted to investigate the enhancement of ultrasound contrast agents in HIFU ablation through experiments that were carried out in vitro and in vivo; an analysis of results of this enhancement mechanism is provided.
引用
收藏
页码:861 / 868
页数:7
相关论文
共 149 条
[1]  
Colombel M(2004)Principles and results of high-intensity focused ultrasound for localized prostate cancer Prostate Cancer Prostatic Dis 7 289-294
[2]  
Gelet A(2004)Perspectives in clinical uses of high-intensity focused ultrasound Ultrasonics 42 1087-1093
[3]  
Clement GT(2004)Emerging technologies in therapeutic ultrasound: thermal ablation to gene delivery Hum Cell 17 7-15
[4]  
Tachibana K(2004)Contrast-enhanced ultrasound assessment of tissue response to high-intensity focused ultrasound Ultrasound Med Biol 30 851-854
[5]  
Kennedy JE(1942)A new method for the generation and use of focused ultrasound in experimental biology J Gen Physiol 26 179-193
[6]  
ter Haar GR(2004)High-intensity ultrasound treatment of blunt abdominal solid organ injury: an animal model J Trauma 57 152-156
[7]  
Wu F(2004)Image-guided HIFU neurolysis of peripheral nerves to treat spasticity and pain Ultrasound Med Biol 30 1199-1207
[8]  
Lynn JG(2002)High-intensity focused ultrasound selectively disrupts the blood-brain barrier in vivo Ultrasound Med Biol 28 389-400
[9]  
Fry WJ(2005)The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population Br J Cancer 93 890-895
[10]  
Meyers R(2004)Local recurrence of prostate cancer after external beam radiotherapy: early experience of salvage therapy using high-intensity focused ultrasonography Urology 63 625-629