An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres

被引:0
作者
Hai-Li Zhang
Guo-Song Lai
De-Yan Han
Ai-Min Yu
机构
[1] Hubei Normal University,Hubei Key Laboratory of Bioanalytical Technique, Department of Chemistry and Environmental Engineering
[2] Murdoch University,School of Chemical and Mathematical Sciences
来源
Analytical and Bioanalytical Chemistry | 2008年 / 390卷
关键词
Horseradish peroxidase; Hydrogen peroxide; Magnetic microspheres; Biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
A new kind of magnetic dextran microsphere (MDMS) with uniform shape and narrow diameter distribution has been prepared from magnetic iron nanoparticles and dextran. Horseradish peroxidase (HRP) was successfully immobilized on the surface of an MDMS-modified glassy-carbon electrode (GCE), and the immobilized HRP displayed excellent electrocatalytic activity in the reduction of H2O2 in the presence of the mediator hydroquinone (HQ). The effects of experimental variables such as the concentration of HQ, solution pH, and the working potential were investigated for optimum analytical performance. This biosensor had a fast response to H2O2 of less than 10 s and an excellent linear relationship was obtained in the concentration range 0.20 μmol L−1–0.68 mmol L−1, with a detection limit of 0.078 μmol L−1 (S/N = 3) under the optimum conditions. The response showed Michaelis–Menten behavior at larger H2O2 concentrations, and the apparent Michaelis–Menten constant \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ K^{{app}}_{M} $$\end{document} was estimated to be 1.38 mmol L−1. Moreover, the selectivity, stability, and reproducibility of the biosensor were evaluated, with satisfactory results.
引用
收藏
页码:971 / 977
页数:6
相关论文
共 153 条
[1]  
Wang L(2004)undefined Electrochem Commun 6 225-229
[2]  
Wang E(2003)undefined Talanta 59 981-988
[3]  
Lei CX(2007)undefined Biosens Bioelectron 22 1268-1274
[4]  
Hu SQ(2007)undefined J Electroanal Chem 599 91-99
[5]  
Shen GL(2003)undefined Anal Bioanal Chem 376 902-907
[6]  
Yu RQ(2005)undefined Anal Chim Acta 553 196-200
[7]  
Chen S(2005)undefined Anal Bioanal Chem 381 1179-1185
[8]  
Yuan R(2000)undefined Anal Biochem 278 22-28
[9]  
Chai Y(2006)undefined Talanta 68 721-727
[10]  
Zhang L(2004)undefined Electroanalysis 16 1122-1131