C1–2 transarticular screws combined with C1 laminar hooks fixation: a modified posterior atlantoaxial fixation technique and outcome in 72 patients

被引:0
|
作者
Bin Ni
Xiang Guo
Ning Xie
Songkai Li
Fengjing Zhou
Feng Zhang
Qi Liu
机构
[1] The Second Military Medical University,Department of Spinal Surgery, The second affiliated hospital
[2] Changzheng Hospital,Department of Orthopedics
来源
European Spine Journal | 2013年 / 22卷
关键词
Cervical spine; Atlantoaxial articulation; Instability; Spinal fusion;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:260 / 267
页数:7
相关论文
共 50 条
  • [41] Accuracy and complications associated with posterior C1 screw fixation techniques: a radiographic and clinical assessment
    Bransford, Richard J.
    Freeborn, Mark A.
    Russo, Anthony J.
    Nguyen, Quynh T.
    Lee, Michael J.
    Chapman, Jens R.
    Bellabarba, Carlo
    SPINE JOURNAL, 2012, 12 (03) : 231 - 238
  • [42] Rheumatoid atlantoaxial instability treated by anterior transarticular C1-C2 fixation. Case report
    Zapalowicz, Krzysztof
    Radek, Maciej
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2013, 47 (03) : 292 - 297
  • [43] Analysis of Risk Factors for Posterior C1 Screw-Related Complication: A Retrospective Study of 358 Posterior C1 Screws
    Yi, Ho Jun
    Hong, Jae Taek
    Lee, Jong Beom
    Park, Jong-Hyeok
    Lee, Jung Jae
    Kim, Il Sup
    Yang, Seung Ho
    Sung, Jae Hoon
    OPERATIVE NEUROSURGERY, 2019, 17 (05) : 509 - 517
  • [44] Posterior C1-C2 arthrodesis. Experience in transarticular and interarticular fixation in 36 patients
    Bescos, A.
    Munoz, J.
    Colet, S.
    Dominguez, C. J.
    Cardiel, I.
    Florensa, R.
    NEUROCIRUGIA, 2011, 22 (02): : 140 - 149
  • [45] Subaxial sagittal alignment and adjacent-segment degeneration after atlantoaxial fixation performed using C-1 lateral mass and C-2 pedicle screws or transarticular screws
    Yoshida, Go
    Kamiya, Mituhiro
    Yoshihara, Hisatake
    Kanemura, Tokumi
    Kato, Fumihiko
    Yukawa, Yasutugu
    Ito, Keigo
    Matsuyama, Yukihiro
    Sakai, Yoshihito
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (04) : 443 - 450
  • [46] Usefulness of titanium mesh cage for posterior C1-C2 fixation in patients with atlantoaxial instability
    Yang, Hwan-Seo
    Kim, Ki-Wan
    Oh, Young-Min
    Eun, Jong-Pil
    MEDICINE, 2017, 96 (36)
  • [47] C1 lateral mass screws for posterior segmental stabilization of the upper cervical spine and a new method of three-point rigid fixation of the C1-C2 complex
    Vilela, Marcelo D.
    Jermani, Charles
    Braga, Bruno P.
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2006, 64 (3B) : 762 - 767
  • [48] Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method
    Paik, Seung-Chull
    Chun, Hyoung-Joon
    Bak, Koang Hum
    Ryu, Jeil
    Choi, Kyu-Sun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 57 (06) : 460 - 464
  • [49] C1-C2 Transarticular Screw Fixation for Atlantoaxial Instability due to Rheumatoid Arthritis A Seven-Year Analysis of Outcome
    Nagaria, Jabir
    Kelleher, Micheal O.
    McEvoy, Linda
    Edwards, Richard
    Kamel, Mahmoud H.
    Bolger, Ciaran
    SPINE, 2009, 34 (26) : 2880 - 2885
  • [50] Management of Unstable C1 Fractures Involving the Lateral Mass: Posterior C1-C2 Screw-Rod Fixation and Fusion
    Zou, Xiaobao
    Yang, Haozhi
    Deng, Chenfu
    Chen, Junlin
    Ma, Rencai
    Ma, Xiangyang
    Xia, Hong
    MEDICAL SCIENCE MONITOR, 2023, 29 : e938600