Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source

被引:0
|
作者
Ş. Turhan
H. Yücel
A. Demirbaş
机构
[1] Ankara Nuclear Research and Training Center (ANRTC),
关键词
Boron; Boric Acid; Neutron Source; Boron Content; Fluence Rate;
D O I
10.1007/s10967-005-0489-z
中图分类号
学科分类号
摘要
A prompt gamma neutron activation analysis (PGAA) setup installed at ANRTC has been used to analyze boron. It consists of a 22.6% REGe detector and a 740 GBq 241Am-Be neutron source moderated with water and paraffin. At the sample irradiation position, the thermal neutron fluence rate measured was 2.36·104 n·m−2· s−1 and the corresponding Cd-ratio was 22 for gold monitor. The absolute detection efficiency in the range of 120–1500 keV was determined using 152Eu standard solution. The sensitivity and detection limit for standard boric acid samples has been determined. The boron content in boric acid prepared from Turkish borate ores is measured to be 15.91±0.46% wt.
引用
收藏
页码:661 / 664
页数:3
相关论文
共 50 条
  • [21] Determination of Boron in Animal Materials by Reactor Neutron Induced Prompt Gamma-Ray Analysis
    S. Miyamoto
    M. Sutoh
    A. Shiomoto
    S. Yamazaki
    K. Nishimura
    C. Yonezawa
    H. Matsue
    M. Hoshi
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 307 - 309
  • [22] Prompt-gamma neutron activation analysis system design: Effects of D-T versus D-D neutron generator source selection
    R. J. Shypailo
    K. J. Ellis
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 71 - 77
  • [23] Prompt gamma neutron activation analysis of 10B and Gd in biological samples at the MEPhI reactor
    Khokhlov, V. F.
    Zaitsev, K. N.
    Beliayev, V. N.
    Kulakov, V. N.
    Lipengolts, A. A.
    Portnov, A. A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S251 - S253
  • [24] A neutron induced prompt gamma-ray spectroscopy system using a 252Cf neutron source for quantitative analysis of aqueous samples
    Y. J. Park
    B. C. Song
    M. I. Chowdhury
    K. Y. Jee
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 260 : 585 - 594
  • [25] Conceptual design of prompt gamma neutron activation analysis facility at Tehran Research Reactor for BNCT application
    Babaeian, K.
    Rahmani, F.
    Kasesaz, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 : 185 - 190
  • [26] Quantitative Prompt Gamma Analysis Using a Focused Cold Neutron Beam
    H. H. Chen-Mayer
    E. A. Mackey
    R. L. Paul
    D. F. R. Mildner
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 391 - 397
  • [27] Quantitative prompt gamma analysis using a focused cold neutron beam
    Chen-Mayer, HH
    Mackey, EA
    Paul, RL
    Mildner, DFR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (02) : 391 - 397
  • [28] Improvement in the practical implementation of neutron source strength calibration using prompt gamma rays
    Khabaz, Rahim
    Rene Vega-Carrillo, Hector
    APPLIED RADIATION AND ISOTOPES, 2013, 78 : 46 - 50
  • [29] Neutron activation analysis with PE moderated Cf-252 neutron source
    Kim, WS
    Kim, HS
    Kim, JY
    Kim, KH
    Kim, YU
    Lee, KP
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 216 (01) : 75 - 79
  • [30] Neutron activation analysis with PE moderated252Cf neutron source
    Wuon-Shik Kim
    Hyon-Soo Kim
    Jong-Youl Kim
    Ki-Hwan Kim
    Yong-Uhn Kim
    Kwang-Pill Lee
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 216 : 75 - 79