Fluorometric Determination of Hydrogen Peroxide in Natural Water Samples by Flow Injection Analysis with a Reaction Column of Peroxidase Immobilized onto Chitosan Beads

被引:0
|
作者
Tetsuyuki Taniai
Akio Sakuragawa
Tadao Okutani
机构
[1] Nihon University,Department of Materials and Applied Chemistry, College of Science and Technology
来源
Analytical Sciences | 1999年 / 15卷
关键词
Hydrogen peroxide; fluorometric determination; flow injection analysis; immobilized enzyme; horseradish peroxidase; chitosan beads; -(hydroxyphenyl)propionic acid;
D O I
暂无
中图分类号
学科分类号
摘要
It was found that a FIA system with an immobilized enzyme reaction column could be utilized for the determinations of hydrogen peroxide in some water samples, such as rain water and tap water. A column was packed with chitosan beads immobilizing horseradish peroxidase. Under the recommended conditions, it took 5 min for each assay, and the detection limit, which was defined as a signal-to-noise ratio of 3, was 3.0 ng dm−3 of hydrogen peroxide. The relative standard deviation at 1.0 mg dm−3 of hydrogen peroxide was 1.5% (n=20). There was no interference from some coexisting substances having a low oxidation-reduction ability or not; therefore, a standard addition method could be applied to rain water and tap water samples. From such results, it has become clear that the proposed FIA system can be applied to the determination of hydrogen peroxide in water samples, and that the system is suitable for routine analysis in environmental observations.
引用
收藏
页码:1077 / 1082
页数:5
相关论文
共 48 条
  • [21] Determination of hydrogen peroxide using flow injection analysis-conductivity method with ion chromatography
    Wang, KX
    Xu, LJ
    Yao, M
    Zhu, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (05) : 555 - 558
  • [22] Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYST, 1997, 122 (09) : 985 - 989
  • [23] A novel enhancing flow-injection chemiluminescence method for the determination of glutathione using the reaction of luminol with hydrogen peroxide
    Wang, L
    Li, YX
    Zhao, DH
    Zhu, CQ
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 41 - 45
  • [24] Flow injection spectrophotometry coupled with a crushed barium sulfate reactor column for the determination of sulfate ion in water samples
    Burakham, R
    Higuchi, K
    Oshima, M
    Grudpan, K
    Motomizu, S
    TALANTA, 2004, 64 (05) : 1147 - 1150
  • [25] Differential amperometric determination of hydrogen peroxide in honeys using flow-injection analysis with enzymatic reactor
    de Abreu Franchini, Romulo Augusto
    Costa Matos, Maria Auxiliadora
    Colombara, Rosana
    Matos, Renato Camargo
    TALANTA, 2008, 75 (01) : 301 - 306
  • [26] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF MICRO-AMOUNTS OF SULFATE ION IN SURFACE-WATER AND SEA-WATER SAMPLES WITH A BARIUM CHROMATE REACTION COLUMN
    SAKURAGAWA, A
    NAKAYAMA, S
    OKUTANI, T
    ANALYTICAL SCIENCES, 1994, 10 (01) : 77 - 81
  • [27] Determination of Trace Nickel in Natural Water by Flow Injection Analysis with Cetrimonium Bromide as Sensitizer
    Zhao, Z. X.
    Zhang, C. X.
    Li, N.
    Zhang, X. S.
    JOURNAL OF APPLIED SPECTROSCOPY, 2015, 82 (05) : 882 - 887
  • [28] Determination of Trace Nickel in Natural Water by Flow Injection Analysis with Cetrimonium Bromide as Sensitizer
    Z. X. Zhao
    C. X. Zhang
    N. Li
    X. S. Zhang
    Journal of Applied Spectroscopy, 2015, 82 : 882 - 887
  • [29] A peroxidase-tetrathiafulvalene biosensor based on self-assembled monolayer modified Au electrodes for the flow-injection determination of hydrogen peroxide
    Campuzano, S
    Pedrero, M
    Pingarrón, JA
    TALANTA, 2005, 66 (05) : 1310 - 1319
  • [30] Determination of phenol by flow-injection with chemiluminescence detection based on the hemin-catalysed luminol-hydrogen peroxide reaction
    Liu, Wenwen
    Cao, Wei
    Liu, Weihua
    Du, Kang
    Gong, Pixue
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 85 (01) : 283 - 287