Interobserver Comparison of CT and MRI-Based Prostate Apex Definition Clinical Relevance for Conformal Radiotherapy Treatment PlanningClinical Relevance for Conformal Radiotherapy Treatment Planning

被引:0
|
作者
Stefan Wachter
Natascha Wachter-Gerstner
Thomas Bock
Gregor Goldner
György Kovacs
Annette Fransson
Richard Pötter
机构
[1] Department of Radiotherapy and Radiobiology,
[2] University Hospital Vienna,undefined
[3] Austria,undefined
[4] Interdisziplinary Center of Brachytherapy,undefined
[5] University Hospital Kiel,undefined
[6] Germany,undefined
[7] Department of Hospital Physics,undefined
[8] Karolinska Hospital,undefined
[9] Stockholm,undefined
[10] Sweden,undefined
来源
Strahlentherapie und Onkologie | 2002年 / 178卷
关键词
Key Words: Prostate; Apex; MRI; Conformal radiotherapy; Schlüsselwörter: Prostata; Apex; MRT; Konformale Radiotherapie;
D O I
暂无
中图分类号
学科分类号
摘要
CT is widely used for conformal radiotherapy treatment planning of prostate carcinoma. Its limitations are especially at the prostatic apex which cannot be separated from the urogenital diaphragm. The aim of this study was to compare the localization of the prostatic apex in CT and axial MRI to the sagittal MRI in an interobserver analysis.
引用
收藏
页码:263 / 268
页数:5
相关论文
共 11 条
  • [1] Interobserver comparison of CT and MRI-based prostate apex definition -: Clinical relevance for conformal radiotherapy treatment planning
    Wachter, S
    Wachter-Gerstner, N
    Bock, T
    Goldner, G
    Kovacs, G
    Fransson, A
    Pötter, R
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 (05) : 263 - 268
  • [2] Treatment planning evaluation of non-coplanar techniques for conformal radiotherapy of the prostate
    Bedford, JL
    Henrys, AJ
    Dearnaley, DP
    Khoo, VS
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 287 - 292
  • [3] Dosimetry and radiobiologic model comparison of IMRT and 3D conformal radiotherapy in treatment of carcinoma of the prostate
    Luxton, G
    Hancock, SL
    Boyer, AL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01): : 267 - 284
  • [4] The comparison of 5-field conformal radiotherapy techniques for the treatment of prostate cancer: The best for femoral head sparing
    Zare, Mahkameh
    Lashkari, Marzieh
    Ghalehtaki, Reza
    Ghasemi, Arash
    Manshadi, Hamidreza Dehghan
    Mir, Ali
    Noorollahi, Somayeh
    Alamolhoda, Mahboobeh
    MEDICAL DOSIMETRY, 2016, 41 (04) : 296 - 299
  • [5] Treatment outcomes of three-dimensional conformal radiotherapy for localized prostate carcinoma - A large community-based experience
    McCloskey, SA
    Ellerbroek, NA
    McCarthy, L
    Malcolm, AW
    Tao, ML
    Wollman, RC
    Rose, CM
    CANCER, 2004, 101 (11) : 2693 - 2700
  • [6] IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC A direct comparison of PET-based treatment planning
    Fleckenstein, Jochen
    Kremp, Katharina
    Kremp, Stephanie
    Palm, Jan
    Ruebe, Christian
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 75 - 82
  • [7] Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk
    Fenoglietto, Pascal
    Laliberte, Benoit
    Allaw, Ali
    Ailleres, Norbert
    Idri, Katia
    Hay, Meng Huor
    Moscardo, Carmen Llacer
    Gourgou, Sophie
    Dubois, Jean-Bernard
    Azria, David
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 (01) : 77 - 87
  • [8] Radiotherapy of Liver MetastasesComparison of Target Volumes and Dose-Volume Histograms Employing CT- or MRI-Based Treatment PlanningStrahlentherapie von Lebermetastasen. Vergleich von Zielvolumina und Dosis-Volumen-Histogrammen mittels MRT- und CT-gestützter Bestrahlungsplanung
    Maciej Pech
    Konrad Mohnike
    Gero Wieners
    Ewa Bialek
    Oliver Dudeck
    Max Seidensticker
    Nils Peters
    Peter Wust
    Günther Gademann
    Jens Ricke
    Strahlentherapie und Onkologie, 2008, 184 (5) : 256 - 261
  • [9] Generating pseudo-computerized tomography (P-CT) scan images from magnetic resonance imaging (MRI) images using machine learning algorithms based on fuzzy theory for radiotherapy treatment planning
    Moteghaed, Niloofar Yousefi
    Mostaar, Ahmad
    Azadeh, Payam
    MEDICAL PHYSICS, 2021, 48 (11) : 7016 - 7027
  • [10] Retrospective comparison of rectal toxicity between carbon-ion radiotherapy and intensity-modulated radiation therapy based on treatment plan, normal tissue complication probability model, and clinical outcomes in prostate cancer
    Fukata, Kyohei
    Kawamura, Hidemasa
    Kubo, Nobuteru
    Kanai, Tatsuaki
    Torikoshi, Masami
    Nakano, Takashi
    Tashiro, Mutsumi
    Ohno, Tatsuya
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 90 : 6 - 12