Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing

被引:0
作者
Riccardo Faletti
Marco Gatti
Stefano Salizzoni
Laura Bergamasco
Rodolfo Bonamini
Domenica Garabello
Walter Grosso Marra
Michele La Torre
Mara Morello
Simona Veglia
Paolo Fonio
Mauro Rinaldi
机构
[1] University of Turin,Department of Surgical Sciences, Radiology Institute
[2] University of Turin,Division of Cardiac Surgery, Department of Surgical Sciences
[3] University of Turin,Department of Surgical Sciences
[4] S.C. Radiodiagnostica Ospedaliera,Department of Radiodiagnostic
[5] University of Turin,Division of Cardiology, Department of Medical Sciences,
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
Aortic stenosis; Transcatheter aortic valve implantation; Transesophageal echocardiography; Cardiovascular computed tomography; Cardiovascular magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland–Altman (BA) plots, Wilcoxon’s and Friedman’s tests; trends were explored with scatter plots. Categorical variables were studied with Fisher’s exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).
引用
收藏
页码:1255 / 1263
页数:8
相关论文
共 180 条
[41]  
Rinaldi M(undefined)undefined undefined undefined undefined-undefined
[42]  
Kodali SK(undefined)undefined undefined undefined undefined-undefined
[43]  
Williams MR(undefined)undefined undefined undefined undefined-undefined
[44]  
Smith CR(undefined)undefined undefined undefined undefined-undefined
[45]  
Svensson LG(undefined)undefined undefined undefined undefined-undefined
[46]  
Webb JG(undefined)undefined undefined undefined undefined-undefined
[47]  
Makkar RR(undefined)undefined undefined undefined undefined-undefined
[48]  
Jabbour A(undefined)undefined undefined undefined undefined-undefined
[49]  
Ismail TF(undefined)undefined undefined undefined undefined-undefined
[50]  
Moat N(undefined)undefined undefined undefined undefined-undefined