Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing

被引:0
作者
Riccardo Faletti
Marco Gatti
Stefano Salizzoni
Laura Bergamasco
Rodolfo Bonamini
Domenica Garabello
Walter Grosso Marra
Michele La Torre
Mara Morello
Simona Veglia
Paolo Fonio
Mauro Rinaldi
机构
[1] University of Turin,Department of Surgical Sciences, Radiology Institute
[2] University of Turin,Division of Cardiac Surgery, Department of Surgical Sciences
[3] University of Turin,Department of Surgical Sciences
[4] S.C. Radiodiagnostica Ospedaliera,Department of Radiodiagnostic
[5] University of Turin,Division of Cardiology, Department of Medical Sciences,
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
Aortic stenosis; Transcatheter aortic valve implantation; Transesophageal echocardiography; Cardiovascular computed tomography; Cardiovascular magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland–Altman (BA) plots, Wilcoxon’s and Friedman’s tests; trends were explored with scatter plots. Categorical variables were studied with Fisher’s exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).
引用
收藏
页码:1255 / 1263
页数:8
相关论文
共 180 条
[1]  
Nkomo VT(2006)Burden of valvular heart diseases: a population-based study Lancet 368 1005-1011
[2]  
Gardin JM(2010)Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 1597-1607
[3]  
Skelton TN(2011)Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2187-2198
[4]  
Gottdiener JS(2015)Pre-transcatheter aortic valve implantation workup in the cardiac catheterisation laboratory Heart Lung Circ 24 1162-1170
[5]  
Scott CG(2011)Outcome of patients after transcatheter aortic valve embolization J Am Coll Cardiol Cardiovasc Interv 4 228-234
[6]  
Enriquez-Sarano M(2012)Rupture of the device landing zone during transcatheter aortic valve implantation: a life-threatening but treatable complication Circ Cardiovasc Interv 5 424-432
[7]  
Leon MB(2014)An iatrogenic atrioventricular septal defect that developed following transfemoral TAVI J Heart Valve Dis 23 216-218
[8]  
Smith CR(2012)Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 1686-1695
[9]  
Mack M(2011)Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography J Am Coll Cardiol 58 2165-2173
[10]  
Miller DC(2013)Medium term outcomes of transapical aortic valve implantation: results from the Italian registry of trans-apical aortic valve implantation Ann Thorac Surg 96 830-835