Management of pediatric radiation dose using Philips digital radiography

被引:0
|
作者
U. Neitzel
机构
[1] Philips Medical Systems,
来源
Pediatric Radiology | 2004年 / 34卷
关键词
Digital radiography; Radiation dose; Image quality; Pediatrics;
D O I
暂无
中图分类号
学科分类号
摘要
Digital radiography systems based on flat-panel detectors have been introduced into clinical practice in the past few years. The high detective quantum efficiency of these detectors allows the radiation dose to be reduced while maintaining image quality, an issue particularly significant for pediatric radiography. Another important aspect for dose optimization and monitoring is the integration of the detector into a computer-controlled x-ray examination system. This enables full control and complete reporting of all dose-relevant exposure parameters, including the determination of the exposure indicator and the patient dose (kerma-area product). In this paper the implementation of these principles in the Philips Digital Diagnost DR system is described and their relevance for pediatric applications is discussed.
引用
收藏
页码:S227 / S233
相关论文
共 50 条
  • [21] Reduction of radiation dose by using digital luminescence radiography on a hand phantom.
    Heyne, JP
    Merbold, H
    Sehner, J
    Neumann, R
    Adler, R
    Freesmeyer, M
    Kaiser, WA
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (04): : 386 - 390
  • [22] Optimizing Image Quality and Dose for Digital Radiography of Distal Pediatric Extremities Using the Contrast-to-Noise Ratio
    Hess, R.
    Neitzel, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (07): : 643 - 649
  • [23] ASSESSMENT OF RADIATION-DOSE IN DIGITAL STORAGE PHOSPHOR RADIOGRAPHY
    BICK, U
    FIEBICH, M
    LENZEN, H
    WIESMANN, W
    PETERS, PE
    RADIOLOGE, 1991, 31 (01): : 8 - 10
  • [24] Assessment Of Radiation Dose In Digital Radiography System -A Review Article
    Pise, Kunal
    Tivaskar, Suhas
    Luharia, Anurag
    Dhande, Rajasbala
    Pathade, Aniket
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 69 - 75
  • [25] Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool
    Brady, S. L.
    Kaufman, R. A.
    MEDICAL PHYSICS, 2015, 42 (05) : 2489 - 2497
  • [26] DIGITAL RADIOGRAPHY AS A TOOL FOR THE KINEMATIC ANALYSIS OF THE SHOULDER JOINT - A STUDY OF RADIATION-DOSE
    MICHIELS, I
    MOHR, W
    SCHILD, HH
    PAIER, KP
    GREVENSTEIN, J
    BIOMEDIZINISCHE TECHNIK, 1991, 36 (06): : 149 - 152
  • [27] The Image Gently Pediatric Digital Radiography Safety Checklist: Tools for Improving Pediatric Radiography
    John, Susan D.
    Moore, Quentin T.
    Herrmann, Tracy
    Don, Steven
    Powers, Kevin
    Smith, Susan N.
    Morrison, Greg
    Charkot, Ellen
    Mills, Thalia T.
    Rutz, Lois
    Goske, Marilyn J.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (10) : 781 - 788
  • [28] Radiation dose for pediatric scoliosis patients undergoing whole spine radiography: Effect of the radiographic length in an auto-stitching digital radiography system
    Hwang, Yi-Shuan
    Lai, Po-Liang
    Tsai, Hui-Yu
    Kung, Yung-Chuan
    Lin, Yu-Ying
    He, Ren-Jhan
    Wu, Chen-Te
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 99 - 106
  • [29] Options for radiation dose optimisation in pelvic digital radiography: A phantom study
    Manning-Stanley, Anthony S.
    Ward, Anthony J.
    England, Andrew
    RADIOGRAPHY, 2012, 18 (04) : 256 - 263
  • [30] DIGITAL RADIOGRAPHY IN UROLOGIC IMAGING - RADIATION-DOSE REDUCTION ON URETHROCYSTOGRAPHY
    ZOELLER, G
    MAY, C
    VOSSHENRICH, R
    GRABBE, E
    SCHROEDERPRINTZEN, I
    WEIDNER, W
    RINGERT, RH
    UROLOGIC RADIOLOGY, 1992, 14 (01) : 56 - 58