Size-exclusion liquid chromatography of poly(N-vinylformamide)s in aqueous solutions

被引:0
|
作者
V. D. Krasikov
N. I. Gorshkov
I. I. Malakhova
O. S. Egorova
Yu. V. Pokhvoshchev
机构
[1] Russian Academy of Sciences,Institute of Macromolecular Compounds
来源
Journal of Analytical Chemistry | 2017年 / 72卷
关键词
size-exclusion chromatography; velocity sedimentation; polyelectrolytes; poly(; -vinylamide)s; hydrodynamic sizes; intrinsic viscosity; molecular-weight characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
The exclusion mechanism of the separation of poly(N-vinylformamide) and its derivatives with a cysteamine terminal group in gel permeation chromatography implemented by the suppression of polyelectrolyte swelling and the electroexclusion of macromolecules was established by the transport analytical methods of molecular hydrodynamics (HPLC, velocity sedimentation, and intrinsic viscosity). Based on an analysis of the hydrodynamic characteristics and molecular weights of polymer fractions determined by velocity sedimentation, it was found that the molecular characteristics and polydispersity of the water-soluble poly(N-vinylamide) s of aliphatic carboxylic acids and their derivatives can be calculated with the use of the Benoit universal calibration dependence.
引用
收藏
页码:460 / 467
页数:7
相关论文
共 50 条
  • [41] Retention of Large Biological Molecules by Size-Exclusion Chromatography
    Lee, Yu Ri
    Li, Xiaoxia
    Ma, Wanwan
    Row, Kyung Ho
    ANALYTICAL LETTERS, 2017, 50 (06) : 905 - 915
  • [42] Characterization of mixed solutions of hyperbranched and linear polystyrenes by a combination of size-exclusion chromatography and analytical ultracentrifugation
    Zhang, Miao
    Hao, Nairong
    Gao, Yating
    Li, Lianwei
    Ye, Xiaodong
    JOURNAL OF POLYMER SCIENCE, 2020, 58 (05) : 756 - 765
  • [43] CONCENTRATION-EFFECT IN HYALURONAN ANALYSIS BY SIZE-EXCLUSION CHROMATOGRAPHY
    ORVISKY, E
    SOLTES, L
    ALASSAF, S
    CHROMATOGRAPHIA, 1994, 39 (5-6) : 366 - 368
  • [44] Relation between the kinetic and equilibrium quantities in size-exclusion chromatography
    Netopilík, M
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1038 (1-2) : 67 - 75
  • [45] Size-exclusion chromatography using core-shell particles
    Pirok, Bob W. J.
    Breuer, Pascal
    Hoppe, Serafine J. M.
    Chitty, Mike
    Welch, Emmet
    Farkas, Tivadar
    van der Wal, Sjoerd
    Peters, Ron
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1486 : 96 - 102
  • [46] Protein refolding at high concentration using size-exclusion chromatography
    Batas, D
    Chaudhuri, JB
    BIOTECHNOLOGY AND BIOENGINEERING, 1996, 50 (01) : 16 - 23
  • [47] SIZE-EXCLUSION CHROMATOGRAPHY OF ALUMINUM SPECIES IN NATURAL-WATERS
    ZERNICHOW, L
    LUND, W
    ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) : 167 - 171
  • [48] Fractal calibration in size-exclusion chromatography -: I.: An introduction
    García-Lopera, R
    Irurzun, I
    Abad, C
    Campos, A
    JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) : 33 - 43
  • [49] Size-Exclusion Chromatography: A Twenty-First Century Perspective
    Striegel, Andre M.
    CHROMATOGRAPHIA, 2022, 85 (04) : 307 - 313
  • [50] Size-exclusion chromatography of heparin oligosaccharides at high and low pressure
    Ziegler, A
    Zaia, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 837 (1-2): : 76 - 86