Size-exclusion liquid chromatography of poly(N-vinylformamide)s in aqueous solutions

被引:0
|
作者
V. D. Krasikov
N. I. Gorshkov
I. I. Malakhova
O. S. Egorova
Yu. V. Pokhvoshchev
机构
[1] Russian Academy of Sciences,Institute of Macromolecular Compounds
来源
Journal of Analytical Chemistry | 2017年 / 72卷
关键词
size-exclusion chromatography; velocity sedimentation; polyelectrolytes; poly(; -vinylamide)s; hydrodynamic sizes; intrinsic viscosity; molecular-weight characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
The exclusion mechanism of the separation of poly(N-vinylformamide) and its derivatives with a cysteamine terminal group in gel permeation chromatography implemented by the suppression of polyelectrolyte swelling and the electroexclusion of macromolecules was established by the transport analytical methods of molecular hydrodynamics (HPLC, velocity sedimentation, and intrinsic viscosity). Based on an analysis of the hydrodynamic characteristics and molecular weights of polymer fractions determined by velocity sedimentation, it was found that the molecular characteristics and polydispersity of the water-soluble poly(N-vinylamide) s of aliphatic carboxylic acids and their derivatives can be calculated with the use of the Benoit universal calibration dependence.
引用
收藏
页码:460 / 467
页数:7
相关论文
共 50 条
  • [21] Size-exclusion chromatography - a review of calibration methodologies
    Kostanski, LK
    Keller, DM
    Hamielec, AE
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 58 (02): : 159 - 186
  • [22] Toward ideal separation by size-exclusion chromatography
    Netopilik, Milos
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1487 : 139 - 146
  • [23] SIZE-EXCLUSION CHROMATOGRAPHY OF SOYBEAN PROTEINS AND ISOFLAVONES
    COLE, KD
    COUSIN, SL
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (12) : 2713 - 2720
  • [24] SIZE-EXCLUSION CHROMATOGRAPHY OF STRONG POLY-ELECTROLYTES ON POROUS-GLASS COLUMNS
    DUBIN, PL
    TECKLENBURG, MM
    ANALYTICAL CHEMISTRY, 1985, 57 (01) : 275 - 279
  • [25] Viscometric, light scattering, and size-exclusion chromatography studies on the structural changes of aqueous poly(vinyl alcohol) induced by γ-ray irradiation
    Wang, BL
    Mukataka, S
    Kokufuta, E
    Ogiso, M
    Kodama, M
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2000, 38 (01) : 214 - 221
  • [26] Stop-flow reversed phase liquid chromatography x size-exclusion chromatography for separation of peptides
    Xu, Jucai
    Zheng, Lin
    Lin, Lianzhu
    Sun, Baoguo
    Su, Guowan
    Zhao, Mouming
    ANALYTICA CHIMICA ACTA, 2018, 1018 : 119 - 126
  • [27] Problems in the size exclusion chromatography of poly(N-isopropylacrylamide) on styragel columns
    Ya. I. Estrin
    E. O. Perepelitsina
    A. A. Grishchuk
    Russian Journal of Physical Chemistry A, 2016, 90 : 1474 - 1478
  • [28] Evaluation of size-exclusion chromatography for the analysis of phosphorothioate oligonucleotides
    Shimoyama, Atsuko
    Fujisaka, Aid
    Obika, Satoshi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 136 : 55 - 65
  • [29] Thermodynamic equilibrium of the solute distribution in size-exclusion chromatography
    Striegel, AM
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 241 - 245
  • [30] Size-exclusion chromatography of metal nanoparticles and quantum dots
    Pitkanen, Leena
    Striegel, Andre M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 80 : 311 - 320