Analyte-receptor binding kinetics for biosensor applicationsAn analysis of the influence of the fractal dimension on the binding rate coefficient

被引:0
作者
Ajit Sadana
机构
[1] University of Mississippi,Chemical Engineering Department
[2] University,undefined
来源
Applied Biochemistry and Biotechnology | 1998年 / 73卷
关键词
Analyte-receptor; binding coefficient; fractals; kinetics; biosensors;
D O I
暂无
中图分类号
学科分类号
摘要
The diffusion-limited binding kinetics of antigen (analyte), in solution with antibody (receptor) immobilized on a biosensor surface, is analyzed within a fractal framework. Most of the data presented is adequately described by a single-fractal analysis. This was indicated by the regression analysis provided by Sigmaplot. A single example of a dual-fractal analysis is also presented. It is of interest to note that the binding-rate coefficient (k) and the fractal dimension (Df) both exhibit changes in the same and in the reverse direction for the antigen-antibody systems analyzed. Binding-rate coefficient expressions, as a function of the Df developed for the antigen-antibody binding systems, indicate the high sensitivity of thek on the Df when both a single- and a dual-fractal analysis are used. For example, for a single-fractal analysis, and for the binding of antibody Mab 0.5β in solution to gpl20 peptide immobilized on a BIAcore biosensor, the order of dependence on the Df was 4.0926. For a dual-fractal analysis, and for the binding of 25-100 ng/mL TRITC-LPS (lipopolysaccharide) in solution with polymyxin B immobilized on a fiberoptic biosensor, the order of dependence of the binding-rate coefficients, k1 and k2 on the fractal dimensions, Df1 and Df2, were 7.6335 and-11.55, respectively. The fractional order of dependence of thek(s) on the Df(s) further reinforces the fractal nature of the system. Thek(s) expressions developed as a function of the Df(s) are of particular value, since they provide a means to better control biosensor performance, by linking it to the heterogeneity on the surface, and further emphasize, in a quantitative sense, the importance of the nature of the surface in biosensor performance.
引用
收藏
页码:89 / 112
页数:23
相关论文
共 85 条
  • [1] Scheller F. W.(1991)undefined Sensors Actuators 4 197-206
  • [2] Hintsche R.(1992)undefined Biophys. J. 63 215-223
  • [3] Pfeifer D.(1987)undefined Biosensors 3 1-15
  • [4] Schubert D.(1986)undefined J. Theor. Biol. 120 129-142
  • [5] Rediel K.(1985)undefined J. Colloid Interface Sci. 107 560-566
  • [6] Kindevater R.(1982)undefined Anal. Biochem. 127 183-192
  • [7] Pisarchick M. L.(1992)undefined J. Colloid Interface Sci. 151 166-177
  • [8] Gesty D.(1992)undefined Biosens. Bioelectron. 7 559-568
  • [9] Thompson N. L.(1994)undefined Biosens. Bioelectron. 9 45-55
  • [10] Eddowes M. J.(1995)undefined Biosens. Bioelectron. 10 301-316