Removal of arsenate using graphene oxide-iron modified clinoptilolite-based composites: adsorption kinetic and column study

被引:0
作者
Meltem Bilici Baskan
Seçil Hadimlioglu
机构
[1] Pamukkale University,Department of Environmental Engineering
[2] Denizli Metropolitan Municipality,Department of Environmental Protection and Control
来源
Journal of Analytical Science and Technology | / 12卷
关键词
Arsenate removal; Fixed-bed column study; Kinetic study; Graphene oxide; Clinoptilolite; Graphene-based composites;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, graphene oxide (GO), iron modified clinoptilolite (FeZ), and composites of GO-FeZ (GOFeZA and GOFeZB) were synthesized and characterized using SEM, EDS, XRF, FTIR, and pHpzc. The arsenate uptake on composites of GOFeZA and GOFeZB was examined by both kinetic and column studies. The adsorption capacity increases with the increase of the initial arsenate concentration at equilibrium for both composites. At the initial arsenate concentration of 450 μg/L, the arsenate adsorption on GOFeZA and GOFeZB was 557.86 and 554.64 μg/g, respectively. Arsenate adsorption on both composites showed good compatibility with the pseudo second order kinetic model. The adsorption process was explained by the surface complexation or ion exchange and electrostatic attraction between GOFeZA or GOFeZB and arsenate ions in the aqueous solution due to the relatively low equilibrium time and fairly rapid adsorption of arsenate at the beginning of the process. The adsorption mechanism was confirmed by characterization studies performed after arsenate was loaded onto the composites. The fixed-bed column experiments showed that the increasing the flow rate of the arsenate solution through the column resulted in a decrease in empty bed contact time, breakthrough time, and volume of treated water. As a result of the continuous operation column study with regenerated GOFeZA, it was demonstrated that the regenerated GOFeZA has lower breakthrough time and volume of treated water compared to fresh GOFeZA.
引用
收藏
相关论文
共 312 条
  • [1] Abaei Z(2017)Preparation and application of zeolitic adsorbents for removal of fuoride from aqueous solution; equilibrium, kinetic and thermodynamic studies Der Chemica Sinica 8 524-534
  • [2] Faghihian H(2020)Response surface methodology as a statistical tool for optimization of removal of chromium (VI) from aqueous solution by Teff (Eragrostis teff) husk activated carbon App Water Sci 10 1-13
  • [3] Esmaeeli N(2009)Fixed-bed adsorption of reactive azo dye onto granular activated carbon prepared from waste J Hazard Mater 175 298-303
  • [4] Adane T(2020)A critical review on arsenic removal from water using biochar-based sorbents: the significance of modification and redox reactions Chem Eng J 396 125195-720
  • [5] Haile D(2019)Use of (modified) natural adsorbents for arsenic remediation: a review Sci Total Environ 676 706-275
  • [6] Dessie A(2015)Effect of the oxygen-containing functional group of graphene oxide on the aqueous cadmium ions removal Appl Surf Sci 329 269-48
  • [7] Abebe Y(2010)A statistical experiment design approach for arsenic removal by coagulation process using aluminum sulfate Desalination 254 42-403
  • [8] Dagne H(2011)Removal of arsenic from drinking water using modified natural zeolite Desalination 281 396-2691
  • [9] Ahmad AA(2016)Utilization of co-existing iron in arsenic removal from groundwater by oxidation-coagulation at optimized pH J Environ Chem Eng 4 2683-95
  • [10] Hameed BH(2020)Arsenic removal with zero-valent iron filters in Burkina Faso: field and laboratory insights Sci Total Environ 737 139466-478