Anisotropic Investigation of Hard X-ray Emission with Flat Anode Tips in APF Plasma Focus Device

被引:0
|
作者
M. Habibi
R. Amrollahi
机构
[1] Amirkabir University of Technology (Tehran Polytechnic),
来源
Journal of Fusion Energy | 2010年 / 29卷
关键词
Dense plasma focus; Hard X-ray; Magnetic probe; Anode insert; HXR anisotropy;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper behavior of hard X-ray (HXR) anisotropy and its intensity along the anode bar from APF plasma focus facility (16 kV, 36 μf, and 115 nH) with different anode tip materials investigated experimentally. Magnetic probe signals registered to choose only discharges with high degree of current sheath symmetry. The signals obtained by scintillation detectors by a special arrangement at each angular position show that the employment of higher Z anode insert materials not only increase the intensity of HXR signal, but also result to high degree isotropic emission of HXR. The side on emitted intensity along the anode bar has been studied by moving the detector in the direction of central electrode axis. The results confirm the importance of anode tip material on HXR signal intensity.
引用
收藏
页码:119 / 123
页数:4
相关论文
共 27 条
  • [1] Anisotropic Investigation of Hard X-ray Emission with Flat Anode Tips in APF Plasma Focus Device
    Habibi, M.
    Amrollahi, R.
    JOURNAL OF FUSION ENERGY, 2010, 29 (02) : 119 - 123
  • [2] Experimental Study of Hard X-ray Emission with Different Anode Tips in APF Plasma Focus Device
    M. Habibi
    R. Amrollahi
    G. R. Etaati
    Journal of Fusion Energy, 2010, 29 : 49 - 54
  • [3] Experimental Study of Hard X-ray Emission with Different Anode Tips in APF Plasma Focus Device
    Habibi, M.
    Amrollahi, R.
    Etaati, G. R.
    JOURNAL OF FUSION ENERGY, 2010, 29 (01) : 49 - 54
  • [4] Charged particles and x-ray emission studies on a dense plasma focus device
    Chung, S. R.
    Behbahani, R. A.
    Xiao, C.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2020, 175 (11-12): : 1015 - 1020
  • [5] Study of X-ray emission of dense plasma focus device in the presence of external magnetic field
    Mohanty, SR
    Srivastava, MP
    Rawat, RS
    PHYSICS LETTERS A, 1997, 234 (06) : 472 - 476
  • [6] Current sheath dynamics and X-ray emission studies from sequential dense plasma focus device
    Gupta, R
    Moanty, SR
    Rawat, RS
    Srivastava, MP
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2000, 28 (04) : 1263 - 1270
  • [7] Argon Soft X-Ray Scaling Curves for the Amirkabir Plasma Focus Device
    Hadi Barati
    Morteza Habibi
    Journal of Fusion Energy, 2022, 41
  • [8] Argon Soft X-Ray Scaling Curves for the Amirkabir Plasma Focus Device
    Barati, Hadi
    Habibi, Morteza
    JOURNAL OF FUSION ENERGY, 2022, 41 (01)
  • [9] Study of plasma focus as a hard X-ray source for non-destructive testing
    Hussain, S.
    Zakaullah, M.
    MODERN PHYSICS LETTERS B, 2007, 21 (24): : 1643 - 1650
  • [10] X-ray spectral measurements of a dense plasma focus
    Whitlock, RR
    Dozier, CM
    Newman, DA
    Petr, R
    Freshman, J
    Hoey, DW
    Heaton, JL
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS III, 2002, 4781 : 54 - 60