On-line Preconcentration System Using Mini-column Packed with a Chelating Resin for the Characterization of Seasonal Variations of Trace Elements in Seawater by ICP-MS and ICP-AES

被引:0
作者
Takashi Sumida
Tetsuya Nakazato
Hiroaki Tao
Mitsuko Oshima
Shoji Motomizu
机构
[1] Kochi Prefectual Industrial Technology Center,Graduate School of Natural Science and Technology
[2] National Institute of Advanced Industrial Science and Technology,undefined
[3] Okayama University,undefined
来源
Analytical Sciences | 2006年 / 22卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An on-line column preconcentration technique coupled with inductively coupled plasma–mass spectrometry (ICP-MS) and -atomic emission spectrometry (ICP-AES) was developed using a mini-column (ca. 3 mm i.d., 40 mm length), that was packed with chelating resin (0.2 g) of iminodiacetic acid groups, Muromac A-1. After the preconcentration step, the column was washed with ammonium acetate buffer (pH 5.5) and water to remove major elements, such as Ca and Mg, and then eluted with 4 ml of 2 mol l−1 nitric acid. Eleven trace elements (Al, V, Fe, Co, Ni, Cu, Zn, Cd, Pb, Th and U) in seawater were determined by ICP-MS/AES. Recoveries for most of the elements tested were over 90%, although those for Al, V and Th were around 70%. The accuracy of the proposed method was evaluated by analyzing a standard reference material of seawater (NASS-4, NRC Canada). The values of Fe, Co, Ni, Cu, Zn, Cd and Pb obtained with the present method showed good agreement with the certified values as judged from the standard deviation. The method was successfully applied to characterize seasonal variations of trace elements in deep seawater (DSW) and surface seawater (SSW). In addition, no serious decrease in analytical performance of the present column system was observed during the experimental period of about 1 year.
引用
收藏
页码:1163 / 1168
页数:5
相关论文
共 44 条
[31]   Determination of trace elements in natural water samples by air-segmented flow-injection/ICP-MS after preconcentration with a chitosan-based chelating resin [J].
Lee, KH ;
Oshima, M ;
Motomizu, S .
BUNSEKI KAGAKU, 2000, 49 (07) :529-536
[32]   Determination of lead in drinking water by ICP-AES with ultrasonic nebulization and flow-injection on-line preconcentration using an amberlite XAD-16 resin [J].
Wuilloud, RG ;
Acevedo, HA ;
Vazquez, FA ;
Martinez, LD .
ANALYTICAL LETTERS, 2002, 35 (10) :1649-1665
[33]   Determination of trace metal fractionation in aqueous solutions using a solid phase extraction flow injection system on-line coupled to ICP-AES [J].
Puls, Christoph ;
Limbeck, Andreas .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) :1434-1440
[34]   Organic and inorganic selenium speciation in environmental and biological samples by nanometer-sized materials packed dual-column separation/preconcentration on-line coupled with ICP-MS [J].
Huang, Chaozhang ;
Hu, Bin ;
He, Man ;
Duan, Jiankun .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (03) :336-345
[35]   MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION FOR THE ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP-MS) [J].
Zereen, Fahmida ;
Yilmaz, Vedat ;
Arslan, Zikri .
ANALYTICAL LETTERS, 2014, 47 (01) :58-76
[36]   On-Line Separation and Preconcentration of Trace Metals in Biological Samples Using a Microcolumn Loaded with PAN-Modified Nanometer-Sized Titanium Dioxide, and Their Determination by ICP-AES [J].
Lanhao Yang ;
Bin Hu ;
Zucheng Jiang ;
Huilin Pan .
Microchimica Acta, 2004, 144 :227-231
[37]   On-line separation and preconcentration of trace metals in biological samples using a microcolumn loaded with PAN-modified nanometer-sized titanium dioxide, and their determination by ICP-AES [J].
Yang, LH ;
Hu, B ;
Jiang, ZC ;
Pan, HL .
MICROCHIMICA ACTA, 2004, 144 (04) :227-231
[38]   Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn [J].
Yanbei Zhu ;
Ryota Hattori ;
Eiji Fujimori ;
Tomonari Umemura ;
Hiroki Haraguchi .
Analytical Sciences, 2005, 21 :199-203
[39]   Simultaneous on-line preconcentration and determination of trace metals in environmental samples using a modified nanometer-sized alumina packed micro-column by flow injection combined with ICP-OES [J].
Hang, Chaozhang ;
Hu, Bin ;
Jiang, Zucheng ;
Zhang, Nan .
TALANTA, 2007, 71 (03) :1239-1245
[40]   Multielement determination of trace metals in river water (certified reference material, JS']JSAC 0301-1) by high efficiency nebulization ICP-MS after 100-fold preconcentration with a chelating resin-packed minicolumn [J].
Zhu, YB ;
Hattori, R ;
Fujimori, E ;
Umemura, T ;
Haraguchi, H .
ANALYTICAL SCIENCES, 2005, 21 (03) :199-203