Scanning SQUID Microscope NDT System Based on Eddy Current Testing

被引:0
|
作者
C. R. Zhong
Y. S. He
J. W. Liang
L. Ma
D. H. Lin
机构
[1] Yulin Normal University,Department of Physics and Information Science
[2] Chinese Academy of Sciences,Institute of Physics
[3] Chongqing University,JD Duz
来源
Journal of Superconductivity and Novel Magnetism | 2010年 / 23卷
关键词
SQUID; NDT; Eddy current testing; Double-D coil;
D O I
暂无
中图分类号
学科分类号
摘要
A scanning SQUID microscope based on HTS dc SQUID has been developed. The SQUID is mounted inside the insulation vacuum of a cryostat, which is separated from room temperature samples by a 65 μm thick sapphire window. Operating with a double-D exciting coil, it could be assembled to a scanning SQUID microscope Nondestructive Testing (NDT) system based on eddy current testing. The current is excited by an appropriate sinusoidal alternating (double-D coil) current in the conducting material, and then it induces a corresponding magnetic field. The vertical component of the field is then detected by the scanning SQUID system. The distortion of the field could be detected at the regions of discontinuities, such as flaws. Thereby, the defects inside the materials will be detected with neither contact nor destruction.
引用
收藏
页码:981 / 983
页数:2
相关论文
共 50 条
  • [21] Application of Lorentz force eddy current testing and eddy current testing on moving nonmagnetic conductors
    Carlstedt, Matthias
    Porzig, Konstantin
    Uhlig, Robert P.
    Zec, Mladen
    Ziolkowski, Marek
    Brauer, Hartmut
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 519 - 526
  • [22] Development of Eddy Current Testing System Using HTS-SQUID on a Hand Cart for Detection of Fatigue Cracks of Steel Plate Used in Expressways
    Tsukamoto, Akira
    Hato, Tsunehiro
    Adachi, Seiji
    Oshikubo, Yasuo
    Tsukada, Keiji
    Tanabe, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [23] Vector-Based Eddy-Current Testing Method
    Li, Cheng
    Liu, Runcong
    Dai, Shangjun
    Zhang, Nianmei
    Wang, Xiaodong
    APPLIED SCIENCES-BASEL, 2018, 8 (11):
  • [24] Thickness Measuring of Multilayer Conductor Based on Eddy Current Testing
    Li Guohou
    Kang Xusheng
    Huang Pingjie
    Chen Peihua
    Hou Dibo
    Zhang Guangxin
    Zhou Zekui
    CCDC 2009: 21ST CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, PROCEEDINGS, 2009, : 3269 - 3272
  • [25] Characterization and implementation of a GMR based probe for eddy current testing
    Tamburrino, A.
    Ventre, S.
    Ferrigno, L.
    Udpa, S.
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2008, 28 (1-2) : 329 - 336
  • [26] Plating thickness evaluation based on eddy current testing for CGL
    Kosaka D.
    Moriyasu K.
    Kakishita K.
    IEEJ Transactions on Fundamentals and Materials, 2019, 139 (04) : 212 - 218
  • [27] A novel GMR-based eddy current testing platform
    Ye, Bo
    Li, Ming
    Chen, Fei
    International Journal of Multimedia and Ubiquitous Engineering, 2014, 9 (10): : 363 - 374
  • [28] Applicability of eddy current technique in in-bore NDT tool for ITER hydraulic pipe welds
    Noguchi, Yuto
    Tsunokai, Manabu
    Nakata, Kentaro
    Takeda, Nobukazu
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 2571 - 2576
  • [29] Development of eddy current testing system for complicated-shaped components
    Power and Industrial Systems R and D Laboratory, Hitachi, Ltd., 7-2-1 Omika-Cho, Hitachi-Shi, Ibaraki 319-1221, Japan
    不详
    不详
    不详
    不详
    Trans. At. Energy Soc. Jpn., 2008, 2 (142-151): : 142 - 151
  • [30] Rapid flaw depth estimation from SQUID-based eddy current nondestructive evaluation
    Pattabiraman, M.
    Nagendran, R.
    Janawadkar, M. P.
    NDT & E INTERNATIONAL, 2007, 40 (04) : 289 - 293