Comprehensive study of the impacts of surrounding structures on the aero-dynamic performance and flow characteristics of an outdoor unit of split-type air conditioner

被引:0
|
作者
S. A. M. Mehryan
Farshad M. Kashkooli
M. Soltani
机构
[1] Islamic Azad University,Young Researchers and Elite Club, Yasooj Branch
[2] K. N. Toosi University of Technology,Department of Mechanical Engineering
[3] Niroo Research Institute,HVAC&R Management Research Center
[4] University of Waterloo,Department of Earth & Environmental Sciences
[5] Waterloo University,Waterloo Institute for sustainable energy (WISE)
来源
Building Simulation | 2018年 / 11卷
关键词
outdoor unit of split-type air conditioner; axial-flow fan; grille; air throw distance; deflecting-ring’s width; condenser obstruction;
D O I
暂无
中图分类号
学科分类号
摘要
Current paper numerically investigated the effect of three main surrounding structures (exhaust grille, deflecting-ring, and heat exchanger) on airflow characteristics passing through the outdoor unit of split-type air conditioner. Characteristic curves of the fan were obtained, and then simulation results were successfully validated compared to experimental data. Three types of grilles (a circular grille, a rectangular grille, and a proposed novel grille) were evaluated and comprised with two parameters of non-dimensional aero-dynamic and air throw distances. Results indicated the superiority of proposed grille and circular grille, respectively in two mentioned parameters. Increment of the deflecting-ring’s width increased the non-dimensional aero-dynamic performance, the efficiency, and the turbulence intensity and vice versa. Decrement of deflecting ring’s width led to decreasing in these parameters except turbulence intensity. Besides, condenser blockage made a decrease in the non-dimensional aero-dynamic performance and increase in the total pressure coefficient.
引用
收藏
页码:325 / 337
页数:12
相关论文
共 14 条
  • [1] Comprehensive study of the impacts of surrounding structures on the aero-dynamic performance and flow characteristics of an outdoor unit of split-type air conditioner
    Mehryan, S. A. M.
    Kashkooli, Farshad M.
    Soltani, M.
    BUILDING SIMULATION, 2018, 11 (02) : 325 - 337
  • [2] A Study of Effects of Surrounding Structures towards Airflow Performance in the Outdoor Unit of Split-type Air-conditioners
    Wei, Eric Phan Tze
    Shukor, Mohd Hamdi Abdul
    RECENT ADVANCES IN FLUID MECHANICS, 2009, : 15 - 21
  • [3] Investigation of air-flow fields and aeroacoustic noise in outdoor unit for split-type air conditioner
    Jiang, Cai-Ling
    Tian, Jie
    Ouyang, Hua
    Chen, Jiang-Ping
    Chen, Zhi-Jiu
    NOISE CONTROL ENGINEERING JOURNAL, 2006, 54 (03) : 146 - 156
  • [4] Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit
    Zhao, Xifeng
    Sun, Jinju
    Zhang, Zhi
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 1098 - 1108
  • [5] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, (04) : 836 - 845
  • [6] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, 27 (04) : 836 - 845
  • [7] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    Wu Chengjun
    Liu Jiang
    Pan Jie
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2014, 27 (04) : 836 - 845
  • [8] Influence of surrounding structures upon the aerodynamic and acoustic performance of the outdoor unit of a split air-conditioner
    Chengjun Wu
    Jiang Liu
    Jie Pan
    Chinese Journal of Mechanical Engineering, 2014, 27 : 836 - 845
  • [9] Energy saving and performance assessment of a split-type air conditioner integrated by an evaporative cooling unit with nanofluids
    Elsaid, Ashraf Mimi
    Wahba, M. A. I.
    Sharshir, Swellam W.
    Abd Raboo, M. F.
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [10] Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance
    Chow, TT
    Lin, Z
    Liu, JP
    ENERGY AND BUILDINGS, 2002, 34 (03) : 237 - 244