The comparison of edema and ecchymosis after piezoelectric and conventional osteotomy in rhinoplasty

被引:0
作者
Ümit Taşkın
Timur Batmaz
Mehmet Erdil
Salih Aydın
Kadir Yücebaş
机构
[1] Bagcilar Education and Research Hospital,Department of Otorhinolaryngology
[2] Beykent University,Department of Odiometry, Medical Faculty
[3] Bağcılar Hospitalist Hospital,undefined
来源
European Archives of Oto-Rhino-Laryngology | 2017年 / 274卷
关键词
Rhinoplasty; Osteotomy; Edema; Ecchymosis;
D O I
暂无
中图分类号
学科分类号
摘要
The basic aim of our study is to compare the results of the conventional and piezoelectric osteotomy in rhinoplasty by complete subperiosteal degloving of nasal bone to minimize soft-tissue injury. The study was designed as a prospective, double-blind, randomized, and controlled study. Setting is a tertiary referral hospital in Turkey. Ninety patients who underwent primary open rhinoplasty with osteotomy, performed by either the conventional instruments or the piezoelectric device. The complete subperiosteal degloving of the entire nasal bone was done up to the nasal maxillary sulcus, medial canthus, and nasion in all patients, independent of the type of osteotomy device used. Patients subsequently underwent median-oblique and lateral osteotomy, either with an ultrasonic device or a conventional 2-mm guarded, straight osteotome. The postoperative edema and ecchymosis were evaluated by another surgeon who was blinded to the osteotomy procedure on postoperative days 2 and 7. The edema scores were significantly increased on the second day compared with the seventh day in both groups 1 and 2. However, there was no significant difference between groups. The ecchymosis scores were slightly higher in postoperative day 2, compared with day 7, in both groups 1 and 2, but statistically not significant. This study showed that the main reason edema and ecchymosis are seen post-rhinoplasty is related to soft-tissue injury during osteotomy.
引用
收藏
页码:861 / 865
页数:4
相关论文
共 50 条
[31]   Piezoelectric Osteotomy versus Conventional Osteotomy in Rhinoplasty: A Systematic Review and Meta-analysis [J].
Khajuria, Ankur ;
Krzak, Ada M. ;
Reddy, Rohin K. ;
Lai, Kenneth ;
Wignakumar, Thirushan ;
Rohrich, Rod J. .
PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2022, 10 (11)
[32]   Edema, Ecchymosis, and Pain: Classic versus Electric Micro-Saw Osteotomy [J].
Bayrakci, Erdem ;
Aricigil, Mitat ;
Eryilmaz, M. Akif ;
Eravci, Fakih Cihat ;
Arbag, Hamdi .
FACIAL PLASTIC SURGERY, 2025,
[33]   Evaluation of Periorbital Edema and Ecchymosis After Osteotomy in Septorhinoplasty Cases by Measuring Bone Density and Thickness [J].
Demirbaglar, Cagri Can ;
Cil, Ozge Caglar ;
Ozturk, Muhsin Ozgun ;
Tezcan, Erkan ;
Guclu, Oguz .
JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (01) :66-e71
[34]   Evaluation of the Efficacy of Hilotherapy for Postoperative Edema, Ecchymosis, and Pain After Rhinoplasty [J].
Hanci, Deniz ;
Ustun, Onur ;
Yilmazer, Ayca Baskadem ;
Goker, Ayse Enise ;
Karaketir, Semib ;
Uyar, Yavuz .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (09) :1628.e1-1628.e5
[35]   A Comparison Between Piezosurgery and Conventional Osteotomies in Rhinoplasty on Post-Operative Oedema and Ecchymosis: A Systematic Review [J].
Kisel, Janneta ;
Khatib, Manaf ;
Cavale, Naveen .
AESTHETIC PLASTIC SURGERY, 2023, 47 (03) :1144-1154
[36]   A Comparison Between Piezosurgery and Conventional Osteotomies in Rhinoplasty on Post-Operative Oedema and Ecchymosis: A Systematic Review [J].
Janneta Kisel ;
Manaf Khatib ;
Naveen Cavale .
Aesthetic Plastic Surgery, 2023, 47 :1144-1154
[37]   Comparing the piezoelectric and conventional osteotome in rhinoplasty [J].
Hashemi, Sean ;
Noel, Christopher W. ;
Smith, Oakley D. .
AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2023, 44 (02)
[38]   Efficacy of adhesive strips to reduce postoperative periorbital edema and ecchymosis following rhinoplasty [J].
Tatar, Sedat ;
Bulam, Mehmet Hakan ;
Ozmen, Selahattin .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) :34-39
[39]   The effect of periorbital cooling on pain, edema and ecchymosis after rhinoplasty: a randomized, controlled, observer-blinded study [J].
Kayiran, Oguz ;
Calli, Caglar .
RHINOLOGY, 2016, 54 (01) :32-37
[40]   The Effects of Two Different Cold Application Times on Edema, Ecchymosis, and Pain After Rhinoplasty: A Randomized Clinical Trial [J].
Tekin, Yasemin Eda ;
Iyigun, Emine ;
Karakoc, Omer .
JOURNAL OF PERIANESTHESIA NURSING, 2024, 39 (03) :455-460