Measurement of retinal thickness in normal subjects with retinal thickness analyzer

被引:0
作者
Yang Zhikuan
Du Shuhua
机构
[1] Tongji Medical University,Department of Ophthalmology, Tongji Hospital
关键词
retina; retinal thickness; retinal thickness analyzer;
D O I
10.1007/BF02886972
中图分类号
学科分类号
摘要
The retinal thickness at posterior pole of normal subjects was measured by using retinal thickness analyzer (RTA) to determine the values of retinal thickness and to establish map of retinal thickness in normal subjects. The retina of 6 mm × 6 mm in size (approximately 20°, centered on the macula) at the posterior pole was scanned by using RTA to obtain images of 116 normal eyes of 77 cases of various age group. The images were processed by a computer to obtain the retinal thickness values and the thickness map of this location. The data were analyzed with SAS software package. The mean retinal thickness was 171. 77±26. 13 μm with no significant difference among the various age groups (P>0. 05). The thickness maps of the retina of 6 mm × 6 mm size at the posterior pole around the macula rendered a “U”-shaped pattern, extending from the disc to the superior and inferior of the fovea. The retina was found to be thin at temporal side of the fovea, with the thinnest area being at the macula central fovea. The U-shaped pattern of the retinal thickness maps was well in agreement with the topography of the ganglion cells and the retinal nerve fibers in human retina. The measurement of the retinal thickness by RTA reflected the changes in the layers of ganglion cells and the retinal nerve fiber. Each scanning session of RTA examination can yield multiple optical cross-section images of the retina and obtain retinal thickness maps of posterior pole of living eyes.
引用
收藏
页码:314 / 318
页数:4
相关论文
共 50 条
  • [1] Measurement of Retinal Thickness in Normal Subjects with Retinal Thickness Analyzer
    杨智宽
    杜蜀华
    Journal of Tongji Medical University, 1999, (04) : 314 - 318
  • [2] Posterior pole retinal thickness measurements by the retinal thickness analyzer in healthy Chinese subjects
    Chan, Chi-Ming
    Yu, Jy-Haw
    Chen, Li-Ju
    Huang, Che-Hung
    Lee, Chen-Tung
    Lin, Tai-Chih
    Liu, Der-Zen
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (02): : 176 - 181
  • [3] Quantitative analysis of foveal retinal thickness in diabetic retinopathy with the scanning retinal thickness analyzer
    Yasukawa, T
    Kiryu, J
    Tsujikawa, A
    Dong, J
    Suzuma, I
    Takagi, H
    Ogura, Y
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1998, 18 (02): : 150 - 155
  • [4] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [5] Preliminary studies on the application of retinal thickness analyzer in the diagnosis of glaucoma
    Yang Zhikuan
    Du Shuhua
    Current Medical Science, 2000, 20 (3) : 257 - 260
  • [6] Preliminary Studies on the Application of Retinal Thickness Analyzer in the Diagnosis of Glaucoma
    杨智宽
    杜蜀华
    JournalofTongjiMedicalUniversity, 2000, (03) : 257 - 260
  • [7] Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    Neubauer, AS
    Priglinger, S
    Ullrich, S
    Bechmann, M
    Thiel, MJ
    Ulbig, MW
    Kampik, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 596 - 601
  • [8] Retinal thickness in diabetic retinopathy - Comparison of optical coherence tomography, the retinal thickness analyzer, and fundus photography
    Goebel, W
    Franke, R
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (01): : 49 - 57
  • [9] Histological measurement of human retinal thickness
    Yang Zhikuan
    Du Shuhua
    Current Medical Science, 1999, 19 (3) : 246 - 248
  • [10] Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer
    Krist, R
    Hoffmann, EM
    Schwenn, O
    OPHTHALMOLOGE, 2005, 102 (12): : 1175 - +