Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radiodurans

被引:3
作者
Min-Ho Joe
Kang-Hee Lee
Sang-Yong Lim
Seong-Hun Im
Hyun-Pa Song
In Soo Lee
Dong-Ho Kim
机构
[1] Korea Atomic Energy Research Institute,Radiation Research Division for Biotechnology
[2] Hannam University,Department of Biotechnology
[3] Chonnam National University,Interdisciplinary Program of Graduate School for Bioenergy and Biomaterials
来源
Bioprocess and Biosystems Engineering | 2012年 / 35卷
关键词
Cadmium; Whole-cell biosensor; Macroscopic; Red pigment;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, a colorimetric whole-cell biosensor for cadmium (Cd) was designed using a genetically engineered red pigment producing bacterium, Deinococcus radiodurans. Based on the previous microarray data, putative promoter regions of highly Cd-inducible genes (DR_0070, DR_0659, DR_0745, and DR_2626) were screened and used for construction of lacZ reporter gene cassettes. The resultant reporter cassettes were introduced into D. radiodurans R1 to evaluate promoter activity and specificity. Among the promoters, the one derived from DR_0659 showed the highest specificity, sensitivity, and activity in response to Cd. The Cd-inducible activity was retained in the 393-bp deletion fragment (P0659-1) of the P0569 promoter, but the expression pattern of the putative promoter fragments inferred its complex regulation. The detection range was from 10 to 1 mM of Cd. The LacZ expression was increased up to 100 μM of Cd, but sharply decreased at higher concentrations. For macroscopic detection, the sensor plasmid (pRADI-P0659-1) containing crtI as a reporter gene under the control of P0659-1 was introduced into a crtI-deleted mutant strain of D. radiodurans (KDH018). The color of this sensor strain (KDH081) changed from light yellow to red by the addition of Cd and had no significant response to other metals. Color change by the red pigment synthesis could be clearly recognized in a day with the naked eye and the detection range was from 50 nM to 1 mM of Cd. These results indicate that genetically engineered D. radiodurans (KDH081) can be used to monitor the presence of Cd macroscopically.
引用
收藏
页码:265 / 272
页数:7
相关论文
共 108 条
[51]  
Bailone A(undefined)undefined undefined undefined undefined-undefined
[52]  
Devoret R(undefined)undefined undefined undefined undefined-undefined
[53]  
Joe MH(undefined)undefined undefined undefined undefined-undefined
[54]  
Jung SW(undefined)undefined undefined undefined undefined-undefined
[55]  
Im SH(undefined)undefined undefined undefined undefined-undefined
[56]  
Lim SY(undefined)undefined undefined undefined undefined-undefined
[57]  
Song HP(undefined)undefined undefined undefined undefined-undefined
[58]  
Kwon O(undefined)undefined undefined undefined undefined-undefined
[59]  
Kim DH(undefined)undefined undefined undefined undefined-undefined
[60]  
Permina EA(undefined)undefined undefined undefined undefined-undefined