Nonlinear electromechanical response of the ferroelectret ultrasonic transducers

被引:0
|
作者
Joachim Döring
Viktor Bovtun
Jürgen Bartusch
Anton Erhard
Marc Kreutzbruck
Yuriy Yakymenko
机构
[1] Federal Institute for Materials Research and Testing,
[2] Institute of Physics ASCR,undefined
[3] NTUU “Kyiv Polytechnic Institute”,undefined
来源
Applied Physics A | 2010年 / 100卷
关键词
Acoustic Impedance; Coupling Factor; Amplitude Versus; Exciting Pulse; Ultrasonic Transmission;
D O I
暂无
中图分类号
学科分类号
摘要
The ultrasonic transmission between two air-coupled polypropylene (PP) ferroelectret (FE) transducers in dependence on the amplitude of the high-voltage exciting pulse revealed a strongly nonlinear electromechanical response of the FE transmitter. This phenomenon is described by a linear increase of the inverse electromechanical transducer constant \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$t_{33}^{(1)}$\end{document} of the PP FE film with an increase of the exciting electrical pulse amplitude. Enlargement of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$t_{33}^{(1)}$\end{document} by a factor of 4 was achieved by application of 3500 V exciting pulses. The electrostriction contribution to \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$t_{33}^{(1)}$\end{document} can be attributed to the electrostatic force between electrodes and the Maxwell stress effect. The nonlinear electromechanical properties of the PP FE result in a strong increase of its air-coupled ultrasonic (ACUS) figure of merit (FOM) under the high-voltage excitation, which exceeds results of the PP FE technological optimization. The FOM increase can be related to the increase of PP FE coupling factor and/or to the decrease of its acoustic impedance. A significant enhancement of the ACUS system transmission (12 dB) and signal-to-noise ratio (32 dB) was demonstrated by the increase of excitation voltage up to 3500 V. The nonlinear electromechanical properties of the PP FEs seem to be very important for their future applications.
引用
收藏
页码:479 / 485
页数:6
相关论文
共 50 条
  • [1] Nonlinear electromechanical response of the ferroelectret ultrasonic transducers
    Doering, Joachim
    Bovtun, Viktor
    Bartusch, Juergen
    Erhard, Anton
    Kreutzbruck, Marc
    Yakymenko, Yuriy
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2010, 100 (02): : 479 - 485
  • [2] Enhanced electromechanical response of ferroelectret ultrasonic transducers under high voltage excitation
    Bovtun, V.
    Doering, J.
    Bartusch, J.
    Gaal, M.
    Erhard, A.
    Kreutzbruck, M.
    Yakymenko, Y.
    ADVANCES IN APPLIED CERAMICS, 2013, 112 (02) : 97 - 102
  • [3] Ferroelectret non-contact ultrasonic transducers
    V. Bovtun
    J. Döring
    J. Bartusch
    U. Beck
    A. Erhard
    Y. Yakymenko
    Applied Physics A, 2007, 88 : 737 - 743
  • [4] Piezoelectric and electrostrictive effects in ferroelectret ultrasonic transducers
    Doering, Joachim
    Bovtun, Viktor
    Gaal, Mate
    Bartusch, Juergen
    Erhard, Anton
    Kreutzbruck, Marc
    Yakymenko, Yuriy
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (08)
  • [5] Ferroelectret non-contact ultrasonic transducers
    Bovtun, V.
    Doering, J.
    Bartusch, J.
    Beck, U.
    Erhard, A.
    Yakymenko, Y.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2007, 88 (04): : 737 - 743
  • [6] Electromechanical modeling of ultrasonic transducers
    Schmerr, LW
    Dang, CJ
    Sedov, A
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 891 - 898
  • [7] Ferroelectret Ultrasonic Transducers for Pulse-Echo Water Immersion
    Quirce, Julio
    Svilainis, Linas
    Camacho, Jorge
    Gomez Alvarez-Arenas, Tomas
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 14
  • [8] Parameter reproducibility of polypropylene ferroelectret transducers for air-coupled ultrasonic testing
    Gaal, Mate
    Doering, Joachim
    Beck, Uwe
    Weise, Matthias
    Bovtun, Viktor
    Brekow, Gerhard
    Kreutzbruck, Marc
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1673 - 1675
  • [9] Air-coupled ultrasonic transducers based on cellular polypropylene ferroelectret films
    Bovtun, Viktor
    Doering, Joachim
    Bartusch, Jurgen
    Beck, Uve
    Erhard, Anton
    Yakymenko, Yuriy
    FERROELECTRICS, 2007, 353 : 620 - 626
  • [10] Maximizing electromechanical properties of PMN materials for ultrasonic transducers
    Yoon, CH
    Sehirlioglu, A
    Pilgrim, SM
    Bridger, K
    PROCEEDINGS OF THE 2001 12TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, VOLS I AND II, 2001, : 427 - 430