Study on the effects of gadolinium-based MRI contrast medium on X-ray scanning

被引:0
作者
Seung-Man Yu
Yeon Park
Kyung-Rae Dong
Youn-Sang Ji
Eun-Hoe Goo
Dae-Cheol Kweon
Woon-Kwan Chung
Jong-Woong Lee
Jae-Hwan Cho
机构
[1] Seoul National University Hospital,Department of Radiology
[2] Catholic University,Department of Biomedical Engineering
[3] Gwangju Health College University,Department of Radiological Technology
[4] Chosun University,Department of Nuclear Engineering
[5] Soonchunhyang University,Department of Physics
[6] Shin Heung College University,Department of Radiologic Science
[7] Kyung Hee University Hospital,Department of Radiology
[8] Gwangwoon University,Department of Electronics and Communications Engineering
[9] Gyeongsan University College,Department of Radiological Science
[10] Soonchunhyang University,Department of Computer Science and Engineering
来源
Journal of the Korean Physical Society | 2012年 / 60卷
关键词
Gadolinium; K-edge; Hounsfield unit; MRI;
D O I
暂无
中图分类号
学科分类号
摘要
Gadolinium has a higher atomic mass (64) than iodine (53). The K-edge absorption energy of gadolinium is 50.2 keV, which is in the absorbed wavelength range of the X-rays used by a CT scanner, suggesting that it has a high X-ray absorption ability. This study examined the effects of a gadolinium-based MRI contrast medium on the quality (mAs) and the quality (kVp) of radiation during a X-ray scan. A contrast medium phantom was manufactured after diluting the contrast medium to various concentrations. A CT scanner (Siemens, Somatom Senation 64, Germany) was used to obtain images by changing the quality of radiation from 80 kVp to 100, 120, and 140 kVp. At a constant quality of radiation of 120 kVp, the mAs was changed from 100 mAs to 200 and 300 mAs and images were obtained under each condition. The Hounsfield units (HUs) in a test tube were measured for analysis and comparison. The contrast enhancement by the contrast medium for CT scanning was 100% at a tube voltage of 80 kVp. The contrast enhancements at 100 kVp, 120 kVp, and 140 kVp were 93.8%, 87.7%, and 69.5%, respectively. In addition, although the quantity increased a fixed tube voltage, the HU of the test tube remained relatively constant, indicating that the absorption of the contrast medium had little association with the quantity of X-rays but had some correlation with the quality of radiation. A tube voltage of 80 kVp or lower is recommended when a MRI contrast medium is used CT scanning. When MRI scanning and X-ray scanning are conducted together, X-ray scanning should be performed first or after sufficient gadolinium contrast medium has been excreted.
引用
收藏
页码:142 / 148
页数:6
相关论文
共 70 条
  • [1] Holland G. N.(1980)undefined J. Comput. Assist. Tomo. 4 429-undefined
  • [2] Hawkes R. C.(2005)undefined Radiology 235 752-undefined
  • [3] Moore W. S.(1956)undefined J. Pharmacol. Exp. Ther. 116 394-undefined
  • [4] Katzberg R. W.(1988)undefined Invest. Radiol. 23 232-undefined
  • [5] Hoppe J. O.(1990)undefined Radiology 175 621-undefined
  • [6] Larsen A. A.(1995)undefined Radiology 196 439-undefined
  • [7] Coulston F.(1999)undefined Radiology 210 829-undefined
  • [8] Meyer D.(2002)undefined Radiology 223 311-undefined
  • [9] Schaefer M.(1997)undefined Invest. Radiol. 32 690-undefined
  • [10] Bonnemain B.(1990)undefined Radiology 174 17-undefined