Vasomodulation of Tumor Blood Flow: Effect on Perfusion and Thermal Ablation Size

被引:0
作者
Hanping Wu
Agata A. Exner
Tianyi M. Krupka
Brent D. Weinberg
John R. Haaga
机构
[1] Case Western Reserve University,Department of Radiology
[2] Case Western Reserve University,Department of Biomedical Engineering
来源
Annals of Biomedical Engineering | 2009年 / 37卷
关键词
Radiofrequency ablation; CT perfusion; Blood flow; Vasomodulation; Phenylephrine; Hydralazine;
D O I
暂无
中图分类号
学科分类号
摘要
Blood flow is a key factor in the efficacy of radiofrequency (RF) ablation treatment of solid tumors. We hypothesized that vasoactive drugs can modulate tumor blood flow and thereby improve the outcome of this thermal ablation approach. To verify this hypothesis, we measured the tumor perfusion changes in response to phenylephrine (PE) and hydralazine (HYZ) using a CT perfusion method in a rat subcutaneous tumor model. The coagulation sizes induced by RF ablation alone, RF ablation with PE and RF ablation with HYZ were compared. Results demonstrated that HYZ produced a marked decrease in entire tumor and tumor rim blood flow of 31.1 and 29.1%; while PE insignificantly change tumor blood flow (5.1% decrease in whole tumor and 6.0% decrease in tumor rim). A markedly greater coagulation area (0.59 cm2 ± 0.24) was observed when HYZ was administered before RF ablation. No difference was noted in the coagulation area induced by RF ablation alone or the combination of PE injection followed by RF ablation (0.29 cm2 ± 0.13 vs. 0.30 cm2 ± 0.18). Results suggest that HYZ decreases subcutaneous tumor blood flow and enhances the coagulation size induced by RF ablation. PE has little influence on tumor blood flow and does not improve ablation.
引用
收藏
相关论文
共 248 条
[1]  
Ackerman N. B.(1988)Increased capillary flow in intrahepatic tumors due to alpha-adrenergic effects of catecholamines Cancer 61 1550-1554
[2]  
Jacobs R.(2006)Hydralazine target: from blood vessels to the epigenome J. Transl. Med. 4 10-93
[3]  
Bloom N. D.(2003)Applying the right statistics: analyses of measurement studies Ultrasound Obstet. Gynecol. 22 85-518
[4]  
Poon T. T.(1981)Cortical blood flow: thermal diffusion vs isotope clearance Stroke 12 513-129
[5]  
Arce C.(2005)Adrenoceptor subtypes in the control of burn-induced plasma extravasation Burns 31 123-150
[6]  
Segura-Pacheco B.(1984)Abnormal response of tumor vasculature to vasoactive drugs J. Natl. Cancer Inst. 72 145-S268
[7]  
Perez-Cardenas E.(1989)Reduction of tumour blood flow by vasoactive drugs: a role in cancer therapy Biomed. Biochim. Acta 48 S264-561
[8]  
Taja-Chayeb L.(2001)Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT Radiology 218 556-1393
[9]  
Candelaria M.(2000)Heterogeneity of angiogenesis and blood vessel maturation in human tumors: implications for antiangiogenic tumor therapies Cancer Res. 60 1388-153
[10]  
Duennas-Gonzalez A.(1999)Ultrasound-guided percutaneous treatment of hepatocellular carcinoma by radiofrequency hyperthermia with a ‘cooled-tip needle’. A preliminary clinical experience Eur. J. Ultrasound 9 145-26