Determination of melamine in food contact materials using an electrode modified with gold nanoparticles and reduced graphene oxide

被引:0
作者
Ningning Chen
Yuxiao Cheng
Chen Li
Cuiling Zhang
Kai Zhao
Yuezhong Xian
机构
[1] East China Normal University,Department of Chemistry, School of Chemistry and Engineering
[2] Shanghai Entry-Exit Inspection and Quarantine Bureau,undefined
来源
Microchimica Acta | 2015年 / 182卷
关键词
Gold nanoparticles; Reduced graphene oxide; Electrochemical sensor; Melamine; Food contact materials;
D O I
暂无
中图分类号
学科分类号
摘要
We describe an electrochemical sensor for melamine based on a glassy carbon electrode (GCE) modified with reduced graphene oxide that was decorated with gold nanoparticles (AuNP/rGO). The AuNPs/rGO nanocomposite was synthesized by co-reduction of Au(III) and graphene oxide and characterized by transmission electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The response of the modified GCE to melamine was investigated by using hexacyanoferrate as an electrochemical reporter. It is found that the electrochemical response to hexacyanoferrate is increasingly suppressed by increasing concentration of melamine. This is attributed to competitive adsorption of melamine at the AuNP/rGO composite through the interaction between the amino groups of melamine and the AuNPs. The presence of rGO, in turn, provides a platform for a more uniform distribution of the AuNPs and enhances the electron transfer rate of the redox reaction. The findings were used to develop a sensitive method for the determination of melamine. Under optimized conditions, the redox peak current of hexacyanoferrate at a working voltage of 171 mV (vs. SCE) is linearly related to the concentration of melamine in 5.0 to 50 nM range. The method was successfully applied to the determination of melamine in food contact materials.
引用
收藏
页码:1967 / 1975
页数:8
相关论文
共 237 条
[1]  
Akter H(2013)Gold nanoparticle-modified indium tin oxide electrode for highly sensitive electrochemical detection of melamine ECS Electrochem Lett 2 B13-B15
[2]  
Shaikh AA(2009)Detection of melamine in milk products by surface desorption atmospheric pressure chemical ionization mass spectrometry Anal Chem 81 2426-2436
[3]  
Chowdhury TR(2012)A novel electrochemical method for sensitive detection of melamine in infant formula and milk using ascorbic acid as recognition rlement Bull Kor Chem Soc 33 2499-2507
[4]  
Rahman MS(2013)Picomolar melamine enhanced the fluorescence of gold nanoparticles: spectrofluorimetric determination of melamine in milk and infant formulas using functionalized triazole capped gold nanoparticles Biosens Bioelectron 42 267-272
[5]  
Bakshi PK(2012)Research progress on migration of toxic and harmful substances in melamine tableware Plastic Sci Technol 40 75-79
[6]  
Ahammad AJS(2010)Determination of melamine in milk powder, milk and fish feed by capillary electrophoresis: a good alternative to HPLC J Sci Food Agric 90 2178-2182
[7]  
Yang SP(2010)A sensitive and validated method for determination of melamine residue in liquid milk by reversed phase high-performance liquid chromatography with solid-phase extraction Food Control 21 686-691
[8]  
Ding JH(2009)Direct determination of melamine in dairy products by gas chromatography/mass spectrometry with coupled column separation Anal Chim Acta 650 39-43
[9]  
Zheng J(2014)Label-free turn-on fluorescent detection of melamine based on the anti-quenching ability of Hg Biosens Bioelectron 53 76-81
[10]  
Hu B(2009) to gold nanoclusters J Am Chem Soc 131 9496-9497