Digital volume correlation: Three-dimensional strain mapping using X-ray tomography

被引:0
作者
B. K. Bay
T. S. Smith
D. P. Fyhrie
M. Saad
机构
[1] University of California,Orthopaedic Research Laboratories, Department of Orthopaedic Surgery
[2] Davis,Breech Research Laboratory, Bone and Joint Center
[3] Henry Ford Hospital,undefined
来源
Experimental Mechanics | 1999年 / 39卷
关键词
Strain measurement; X-ray tomography; image correlation; trabecular bone;
D O I
暂无
中图分类号
学科分类号
摘要
A three-dimensional extension of two-dimensional digital image correlation has been developed. The technique uses digital image volumes generated through high-resolution X-ray tomography of samples with microarchitectural detail, such as the trabecular bone tissue found within the skeleton. Image texture within the material is used for displacement field measurement by subvolume tracking. Strain fields are calculated from the displacement fields by gradient estimation techniques. Estimates of measurement precision were developed through correlation of repeat unloaded data sets for a simple sum-of-squares displacement-only correlation formulation. Displacement vector component errors were normally distributed, with a standard deviation of 0.035 voxels (1.22 μm). Strain tensor component errors were also normally distributed, with a standard deviation of approximately 0.0003. The method was applied to two samples taken from the thigh bone near the knee. Strains were effectively measured in both the elastic and postyield regimes of material behavior, and the spatial patterns showed clear relationships to the sample microarchitectures.
引用
收藏
页码:217 / 226
页数:9
相关论文
共 113 条
[1]  
Bruck H.A.(1989)Digital Image Correlation Using Newton-Raphson Method of Partial Differential Correction Experimental Mechanics 29 261-267
[2]  
McNeill S.R.(1985)Applications of Digital-image-correlation Techniques to Experimental Mechanics Experimental Mechanics 25 232-244
[3]  
Sutton M.A.(1999)Optimal Image Correlation in Experimental Mechanics Opt. Eng. 33 1099-1105
[4]  
Peters W.H.(1983)Determination of Displacements Using an Improved Digital Correlation Method Image Vis. Computing 1 133-139
[5]  
Chu T.C.(1986)Application of an Optimized Digital Correlation Method to Planar Deformation Analysis Image Vis. Computing 4 143-150
[6]  
Ranson W.F.(1990)Automatic Mark Detection in Electron Beam Nanolithography Using Digital Image Processing and Correlation J. Vacuum Sci. Tech. 8 1994-2001
[7]  
Sutton M.A.(1996)High-temperature Deformation Measurements Using Digital-image Correlation Experimental Mechanics 36 64-70
[8]  
Peters W.H.(1987)Estimation of Stress Intensity Factor by Digital Image Correlation Eng. Fract. Mech. 28 101-112
[9]  
Kahn-Jetter Z.L.(1988)Effects of Subpixel Image Restoration on Digital Correlation Error Estimates Opt. Eng. 27 870-877
[10]  
Jha N.K.(1989)Strain-field Analysis Acquired Through Correlation of X-ray Radiographs of a Fiber-reinforced Composite Laminate Experimental Mechanics 29 237-240