Intensity modulated radiation therapy: Film verification of planar dose maps

被引:3
作者
P. Tangboonduangjit
I. Wu
M. Butson
A. Rosenfeld
P. Metcalfe
机构
[1] University of Wollongong,Centre of Medical Radiation Physics, Dept. of Engineering Physics
[2] Illawarra Cancer Care Centre,Dept. of Radiation Oncology
[3] Chang-Gung Memorial Hospital,undefined
来源
Australasian Physics & Engineering Sciences in Medicine | 2003年 / 26卷 / 4期
关键词
intensity modulated radiation therapy; film dosimetry; Pinnacle;
D O I
10.1007/BF03179181
中图分类号
学科分类号
摘要
A new slow response radiographic film (Kodak EDR) is compared with a more traditional faster responding dosimetry film (Kodak XV) in an intensity modulated radiation therapy x-ray field. Dose profiles derived from the two films are compared with doses obtained using a radiotherapy dose planning system (Philips-Pinnacle) which calculates planar dose using a collapsed cone convolution algorithm. Comparisons of the dose maps delivered from film with the Pinnacle dose maps are useful to ensure accurate dose delivery. The Pinnacle dose maps agreed with measurement using both film types to within ±3% (in the umbral region) at depths ranging from dmax to 15 cm. Both XV and EDR films can be used to verify IMRT. EDR film is better suited for dosimetry for combined field dose maps due to its useful dose range of 1–5 Gy. We found XV to be more suitable for individual field dose maps (dose range 0–1 Gy) as no scaling of monitor units were required to achieve acceptable optical density response.
引用
收藏
页码:194 / 199
页数:5
相关论文
共 89 条
[1]  
Wang X.(1996)Dosimetric verification of intensity modulated field Med. Phys. 23 317-27
[2]  
Spirou S.(1998)Quantitative dosimetric verification of an IMRT planning and delivery system Radiother. Oncol. 49 305-16
[3]  
LoSasso T.(2000)Dose calculation and verification of intensity modulation generated by dynamic multileaf collimators Med. Phys. 27 960-71
[4]  
Stein J.(2001)Verification of dynamic intensity-modulated beam deliveries in canine subjects Med. Phys. 28 2198-2208
[5]  
Chui C. S.(1998)Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy Med. Phys. 25 1919-27
[6]  
Mohan R.(2002)The value of radiographic film for the characterization of intensitymodulated beams Phys. Med. Biol. 47 221-35
[7]  
Low D. A.(2002)Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation Med. Phys. 29 351-55
[8]  
Papatheodorou S.(1996)Dosimetry of high energy photon and electron beams with CEA films Med. Phys. 23 1225-32
[9]  
Rosenwald J. C.(1989)Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media Med. Phys. 16 577-92
[10]  
Zefkili S.(2002)A quality and efficiency analysis of the IMFASTTM segmentation algorithm in head and neck “step & shoot” IMRT treatments Med. Phys. 29 275-83