Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: Evaluation of transesophageal Doppler and electric velocimetry

被引:42
作者
Schubert S. [1 ]
Schmitz T. [1 ]
Weiss M. [2 ]
Nagdyman N. [1 ]
Huebler M. [3 ]
Alexi-Meskishvili V. [3 ]
Berger F. [1 ]
Stiller B. [1 ,4 ]
机构
[1] Department of Congenital Heart Disease/Pediatric Cardiology, Deutsches Herzzentrum Berlin, 13353 Berlin
[2] Department of Anesthesia, University Children's Hospital, Zurich
[3] Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum Berlin, Berlin
[4] Department of Congenital Heart Disease/Pediatric Cardiology, University Children's Hospital Freiburg, Freiburg
关键词
Cardiac output; Doppler echocardiography; Non-invasive; Pediatric; Rlectric velocimetry; Transesophageal Doppler probe;
D O I
10.1007/s10877-008-9133-0
中图分类号
学科分类号
摘要
Background. Continuous a nd non-invasive measurement of cardiac output (CO) may contribute helpful information to the care and treatment of the critically ill pediatric patient. Different methods are available but their clinical verification is still a major problem. Aim. Comparison of reliability and safety of two continuous non-invasive methods with transthoracic echocardiography (TTE) for CO measurement: electric velocimetry technique (EV, Aesculon™) and transesophageal Doppler (TED, CardioQP™). Methods/Material. In 26 infants and children who had undergone corrective cardiac surgery at a median age of 3.5 (1-17) years CO and stroke volume (SV) were obtained by EV, TED and TTE. Each patient had five measurements on the first day after surgery, during mechanical ventilation and sedation. Results. Values for CO and SV from TED and EV correlated well with those of TTE (r = 0.85 and r = 0.88), but mean values were significantly lower than the values of TTE for TED (P = 0.02) and EV (P = 0.001). According to Bland-Altman analysis, bias was 0.36 l/min with a precision of 1.67 l/min for TED vs. TTE and 0.87 l/min (bias) with a precision of 3.26 l/min for EV vs. TTE. No severe adverse events were observed and the handling of both systems was easy in the sedated child. Conclusions. In pediatric patients non-invasive measurement of CO and SV with TED and EV is useful for continuous monitoring after heart surgery. Both new methods seem to underes timate cardiac output in terms of absolute values. However, TED shows tolerable bias and precision and may be helpful for continuous CO monitoring in a deeply sedated and ventilated pediatric patient, e.g. in the operating room or intensive care unit. © Springer Science+Business Media, LLC 2008.
引用
收藏
页码:299 / 307
页数:8
相关论文
共 55 条
  • [1] Estagnasie P., Djedaini K., Mier L., Coste F., Dreyfuss D., Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution, Intensive Care Med, 23, pp. 753-759, (1997)
  • [2] Marcelino P., Germano N., Marum S., Fernandes A.P., Ribeiro P., Lopes M.G., Haemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: A comparative study in liver transplant patients, Acta Med Port, 19, pp. 197-205, (2006)
  • [3] Chew M.S., Poelaert J., Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature, Intensive Care Med, 29, pp. 1889-1894, (2003)
  • [4] Tibby S.M., Hatherill M., Durward A., Murdoch I.A., Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management?, Intensive Care Med, 27, pp. 201-205, (2001)
  • [5] Murdoch I.A., Marsh M.J., Tibby S.M., McLuckie A., Continuous haemodynamic monitoring in children: Use of transoesophageal Doppler, Acta Paediatr, 84, pp. 761-764, (1995)
  • [6] Bearss M.G., Yonutas D.N., Allen W.T., A complication with thermodilution cardiac outputs in centrally-placed pulmonary artery catheters, Chest, 81, (1982)
  • [7] Bossert T., Schmitt D.V., Mohr F.W., Pulmonary artery rupture - Fatal complication of catheter examination (thermodilution catheter), Z Kardiol, 89, (2000)
  • [8] Egan J.R., Festa M., Cole A.D., Nunn G.R., Gillis J., Winlaw D.S., Clinical assessment of cardiac performance in infants and children following cardiac surgery, Intensive Care Med, 31, pp. 568-573, (2005)
  • [9] Botte A., Leclerc F., Riou Y., Sadik A., Neve V., Rakza T., Richard A., Evaluation of a noninvasive cardiac output monitor in mechanically ventilated children, Pediatr Crit Care Med, 7, pp. 231-236, (2006)
  • [10] Ehlers K.C., Mylrea K.C., Waterson C.K., Calkins J.M., Cardiac output measurements. A review of current techniques and research, Ann Biomed Eng, 14, pp. 219-239, (1986)