Influence of idling and short circuits on the self-excitation of a classical double-output induction generator

被引:0
作者
Dzhendubaev A.-Z.R. [1 ]
Barakhoev R.Y. [1 ]
机构
关键词
capacitor self-excitation; double-output induction generator; induction generator;
D O I
10.3103/S1068371213070043
中图分类号
学科分类号
摘要
Experimental results for the capacitor self-excitation of an induction generator with a short-circuited phase rotor and a classical double-output induction generator are compared. The influence of the preceding conditions on the capacitor self-excitation of a classical double-output induction generator is the opposite of that for an induction generator with a short-circuited phase rotor. For the classical double-output induction generator, self-excitation is better after a three-phase short circuit than after idling. © 2013 Allerton Press, Inc.
引用
收藏
页码:403 / 404
页数:1
相关论文
共 4 条
[1]  
Kopylov I.P., Klokov B.K., Spravochnik Po Elektricheskim Mashinam, (1988)
[2]  
Dzhendubaev A.-Z., Hard self-excitation of an induction generator with a short-circuited ferromagnetic rotor, Elektrichestvo, pp. 26-31, (1997)
[3]  
Dzhendubaev A.-Z., Residual emf of an autonomous induction generator with a short-circuited ferromagnetic rotor, Izv. Vyssh. Uchebn. Zaved., Elektromekhan., pp. 39-42, (1999)
[4]  
Barakhoev R., Hard capacitive self-excitation of a classical double-output induction generator, Materialy IV Mezhdunarodnoi Nauchno-prakticheskoi Konferentsii TTS-12, pp. 126-128, (2012)