Erratum to: Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen

被引:0
|
作者
Terue Okamura
Saori Tanaka
Koichi Koyama
Norifumi Nishida
Hideo Daikokuya
Toshiyuki Matsuoka
Kenji Kishimoto
Masakatsu Hatagawa
Hiroaki Kudoh
Ryusaku Yamada
机构
[1] Department of Radiology,
[2] Osaka City University School of Medicine,undefined
[3] 1–4-3,undefined
[4] Ashahi-machi,undefined
[5] Abeno-ku,undefined
[6] Osaka 545-8585,undefined
[7] Japan,undefined
[8] Department of Radiology,undefined
[9] Osaka City University Hospital,undefined
[10] 1–5-7,undefined
[11] Ashahi-machi,undefined
[12] Abeno-ku,undefined
[13] Osaka 545-8586,undefined
[14] Japan,undefined
关键词
D O I
10.1007/s00330-002-1390-6
中图分类号
学科分类号
摘要
引用
收藏
页码:951 / 951
相关论文
共 41 条
  • [31] Development and evaluation of a large-area selenium-based flat panel detector for real-time radiography and fluoroscopy
    Tsukamoto, A
    Yamada, S
    Tomisaki, T
    Asahina, H
    Kinno, A
    Suzuki, K
    RADIOLOGY, 1998, 209P : 358 - 358
  • [32] Clinical application and experimental evaluation of a flat-panel x-ray detector based on amorphous silicon (a-Si): Image quality and potential of dose reduction in skeletal radiography
    Strotzer, M
    Gmeinwieser, JK
    Voelk, M
    Fruend, R
    Seitz, JM
    Spies, V
    RADIOLOGY, 1997, 205 : 1501 - 1501
  • [33] Clinical application of a flat-panel x-ray detector based on amorphous silicon technology:: Image quality and potential for radiation dose reduction in skeletal radiography
    Strotzer, M
    Gmeinwieser, J
    Völk, M
    Fründ, R
    Seitz, J
    Manke, C
    Albrich, H
    Feuerbach, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 23 - 27
  • [34] Contrast-detail phantom study for X-ray spectrum optimization regarding chest radiography using a cesium iodide -: Amorphous silicon flat-panel detector
    Hamer, OW
    Völk, M
    Zorger, N
    Borisch, I
    Büittner, R
    Feuerbach, S
    Strotzer, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (10) : 610 - 618
  • [35] Initial clinical evaluation of new digital subtraction angiography system with a large-area flat panel detector
    Tanaka, S
    Okamura, T
    Nakamura, K
    Okusako, K
    Ikeda, S
    Inoue, Y
    RADIOLOGY, 2002, 225 : 191 - 191
  • [36] Flat-panel X-ray detector based on amorphous silicon versus asymmetric screen-film system: Phantom study of dose reduction and depiction of simulated findings
    Rapp-Bernhardt, U
    Roehl, FW
    Gibbs, RC
    Schmidl, H
    Krause, UW
    Bernhardt, TM
    RADIOLOGY, 2003, 227 (02) : 484 - 492
  • [37] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [38] Digital flat-panel X-ray technology based on cesium iodide and amorphous silicon:: experimental studies and preliminary clinical results.
    Strotzer, M
    Gmeinwieser, J
    Völk, M
    Fründ, R
    Feuerbach, S
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (01): : 66 - 72
  • [39] Digital amorphous silicon flat-panel detector radiography at different exposure doses versus mammography film:: Possibility of radiation dose reduction in detecting rheumatologic bone defects
    Zaehringer, M.
    Reineck, S.
    Perniok, A.
    Krueger, K.
    Andermahr, J.
    Rubbert, A.
    Winnekendonk, G.
    ACTA RADIOLOGICA, 2008, 49 (02) : 157 - 166
  • [40] Digital chest radiography with a large area 43 x 43cm flat panel silicon X-ray detector: Clinical comparison with conventional radiography for visualization of anatomic regions
    Hennigs, SP
    Jaeger, HJ
    Garmer, M
    Gissler, M
    Christmann, A
    Mathias, KD
    RADIOLOGY, 1999, 213P : 429 - 429