In vitro comparison of steady and pulsatile flow characteristics of jellyfish heart valve

被引:0
|
作者
Morsi Y.S. [1 ]
机构
[1] Bio-fluid Dynamics Group, School of Engineering and Science, Swinburne University of Technology, Hawthorn
关键词
Aortic valves; Jellyfish heart valve; Prosthetic valve; Pulsatile flow; Steady flow;
D O I
10.1007/BF02479981
中图分类号
学科分类号
摘要
In examining the hydrodynamic performance of artificial heart valves in vitro, experiments are carried out under either steady or pulsatile flow conditions. Steady flow experiments are simple to set up and analysis of the data is also simple; however, their validity and accuracy have been questioned. In this study, the flow characteristics of jellyfish valves are evaluated and analyzed for steady and pulsatile flow conditions. The analysis is given in terms of velocity and shear stress distributions for a cardiac flow rate of 4.51/min, and the corresponding steady flow rate is measured at two locations, 0.5D and 1D downstream of the valve face (D being the diameter of the pipe). At the 0.5D location, the velocity profile results obtained for both flow conditions indicated that jetting flow occurred close to the wall, and flow reversal as well as stagnation zones occurred in the core of the valve chamber. These phenomena were also evident in the shear stress profiles for both pulsatile and steady flow conditions. At this location, the maximum difference between the steady and pulsatile values of peak velocity is about 18%. However, the maximum difference between the peak shear stresses was in the range of 5%-7%. At the 1D location, the flow characteristics observed under both the pulsatile and steady flow conditions were almost identical, with a maximum difference between the peak values of less than 4%. From the data presented here, it can be stated that, at least in the initial optimization of the valve hemodynamic performance, the steady hydrodynamic evaluation of the valve could be an effective tool for analyzing the flow characteristics.
引用
收藏
页码:143 / 148
页数:5
相关论文
共 50 条
  • [1] STEADY AND PULSATILE FLOW STUDIES ON A TRILEAFLET HEART-VALVE PROSTHESIS
    WOO, YR
    WILLIAMS, FP
    YOGANATHAN, AP
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1983, 17 (03): : 227 - 236
  • [2] A statistical approach to the quantitative comparison of pulsatile flow in vitro data of prosthetic heart valve testing
    Barbaro, V
    Grigioni, M
    Daniele, C
    Boccanera, G
    JOURNAL OF HEART VALVE DISEASE, 1997, 6 (01): : 93 - 100
  • [3] In vitro fluid dynamics of the St Jude valve prosthesis in steady and pulsatile flow
    Hanle, D.D.
    Harrison, E.C.
    Yoganathan, A.P.
    Corcoran, W.H.
    Engineering in Medicine, 1988, 17 (04): : 181 - 187
  • [4] Effects of Heart Rate on the Pulsatile Flow Characteristics of a Stenotic Aortic Valve Model: An In Vitro Experimental Study
    Zhang, Ruihang
    Zhang, Yan
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (10):
  • [5] A statistical approach to the quantitative comparison of pulsatile flow in vitro data of prosthetic heart valve testing - Response
    Bokros, J
    JOURNAL OF HEART VALVE DISEASE, 1997, 6 (01): : 101 - 101
  • [6] PIV measurements of flow distal to polyurethane heart valve prosthesis under steady and pulsatile flow conditions
    Kim, Jung Kyung
    Yoo, Jung Yul
    Sung, Jaeyong
    Chang, Jun Keun
    Min, Byoung Goo
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 43 : 59 - 60
  • [7] PULSATILE FLOW CHARACTERISTICS IN A STENOTIC AORTIC VALVE MODEL: AN IN VITRO EXPERIMENTAL STUDY
    Zhang, Ruihang
    Zhang, Yan
    PROCEEDINGE OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 1, 2019,
  • [8] PULSATILE FLOW EXPERIMENTS ON HEART-VALVE PROSTHESES
    CHANDRAN, KB
    YEARWOOD, TL
    CHEN, CJ
    FALSETTI, HL
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (05) : 529 - 537
  • [9] A COMPARISON OF STEADY AND PULSATILE FLOW IN SYMMETRICALLY BRANCHED TUBES
    WALBURN, FJ
    STEIN, PD
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (01): : 66 - 68
  • [10] IN VITRO FLOW CHARACTERISTICS OF A COMPLETELY FLEXIBLE PROSTHETIC HEART VALVE.
    Davies, Hywel
    Christopher, Robert A.
    Walker, Lance
    1600, (11):