Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

被引:0
|
作者
Vikas Karade
B Ravi
Manish Agarwal
机构
[1] Indian Institute of Technology Bombay,Department of Mechanical Engineering
[2] P.D Hinduja National Hospital & MRC,undefined
来源
Journal of Orthopaedic Surgery and Research | / 7卷
关键词
Megaprosthetic knee replacement; Cutting guide; Tibial component; Tibial cut; Statistical analysis;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 21 条
  • [1] Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement
    Karade, Vikas
    Ravi, B.
    Agarwal, Manish
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2012, 7
  • [2] Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee
    James P Cashman
    Fiona L Carty
    Keith Synnott
    Paddy J Kenny
    Journal of Orthopaedic Surgery and Research, 6
  • [3] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    International Orthopaedics, 2008, 32 : 467 - 471
  • [4] Impact of Use of Intramedullary and Extramedullary Guides on Tibial Component Geometry in Total Knee Replacements: A Systematic Review and Meta-Analysis
    Feeley, Iain
    Hegarty, Aidan
    Hickey, Anne
    Glynn, Aaron
    JOURNAL OF KNEE SURGERY, 2016, 29 (06) : 487 - 496
  • [5] Comparison of Extramedullary Versus Intramedullary Referencing for Tibial Component Alignment in Total Ankle Arthroplasty
    Adams, Samuel B., Jr.
    Demetracopoulos, Constantine A.
    Viens, Nicholas A.
    DeOrio, James K.
    Easley, Mark E.
    Queen, Robin M.
    Nunley, James A., II
    FOOT & ANKLE INTERNATIONAL, 2013, 34 (12) : 1624 - 1628
  • [6] The accuracy of two different extra-medullary tibial cutting guides for posterior tibial slope in total knee arthroplasty
    Bek, Dogan
    Ege, Tolga
    Yildiz, Cemil
    Tunay, Servet
    Basbozkurt, Mustafa
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2014, 25 (02): : 75 - 79
  • [7] Sequential versus automated cutting guides in computer-assisted total knee arthroplasty
    Koulalis, Dimitrios
    O'Loughlin, Padhraig F.
    Plaskos, Christopher
    Kendoff, Daniel
    Cross, Michael B.
    Pearle, Andrew D.
    KNEE, 2011, 18 (06) : 436 - 442
  • [8] Comparison of cementing techniques of the tibial component in total knee replacement
    Tuuli Saari
    Ming Guo Li
    David Wood
    Bo Nivbrant
    International Orthopaedics, 2009, 33 : 1239 - 1242
  • [9] Tibial component in total knee replacement : the effect of overhang and sizing on outcome
    Foubert, Knud
    Heylen, Steven
    Plaeke, Philip
    Somville, Johan
    Nicolai, Paul
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (04): : 659 - 663
  • [10] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08) : 1209 - 1215