An immunoassay cassette with a handheld reader for HIV urine testing in point-of-care diagnostics

被引:0
|
作者
Wenbo Yang
Dianlong Yang
Shisong Gong
Xiaobing Dong
Luyao Liu
Shengda Yu
Xiaolei Zhang
Shengxiang Ge
Dong Wang
Ningshao Xia
Duli Yu
Xianbo Qiu
机构
[1] Beijing University of Chemical Technology,Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology
[2] Beijing Wantai Biological Pharmacy Enterprise Co. Ltd.,National Institute of Diagnostics and Vaccine Development in Infectious Diseases
[3] Xiamen University,undefined
[4] Beijing Advanced Innovation Center for Soft Matter Science and Engineering,undefined
来源
Biomedical Microdevices | 2020年 / 22卷
关键词
HIV test; Urine; Immunoassay; Lateral flow strip; Microfluidic cassette; Handheld optical reader; Point-of-Care (POC) diagnosis;
D O I
暂无
中图分类号
学科分类号
摘要
Currently, most HIV tests are performed with blood samples, or alternatively saliva samples are used for HIV testing. Simple HIV tests need to be performed in hospitals or other medical agencies instead of more invasive HIV blood tests. To enable point-of-care (POC) HIV diagnostics, based on a recently developed lateral flow strip for HIV urine testing, a microfluidic immunoassay cassette with a handheld optical reader is developed. Based on lateral flow strip with gold colloid reporter, the integrated immunoassay cassette can perform sample introduction, metering, discharging, applying and detection which simplifies HIV testing. An indicator is incorporated into the cassette to guide sample introduction based on color change, and further, the excess test sample is stored inside the sealed cassette to avoid any contamination. The low-cost handheld optical reader can provide a test result within a few seconds, which is useful for simple, sensitive and affordable HIV onsite detection. Instead of using normal white LEDs, a customized back light module embedded with green LEDs is adopted to illuminate the lateral flow strip with an appropriate working current to achieve optimal performance. Compared to the standard lateral flow strips using a benchtop reader, with the disposable immunoassay cassette assisted by the handheld optical reader, more convenient, easier-to-operate, and more affordable HIV urine testing can be achieved in POC diagnostics.
引用
收藏
相关论文
共 50 条
  • [1] An immunoassay cassette with a handheld reader for HIV urine testing in point-of-care diagnostics
    Yang, Wenbo
    Yang, Dianlong
    Gong, Shisong
    Dong, Xiaobing
    Liu, Luyao
    Yu, Shengda
    Zhang, Xiaolei
    Ge, Shengxiang
    Wang, Dong
    Xia, Ningshao
    Yu, Duli
    Qiu, Xianbo
    BIOMEDICAL MICRODEVICES, 2020, 22 (02)
  • [2] Lateral Flow Immunoassay Reader Technologies for Quantitative Point-of-Care Testing
    Park, Jongwon
    SENSORS, 2022, 22 (19)
  • [3] Development in competitive immunoassay of a point-of-care testing for cotinine (COT) detection in urine
    Konziw, Suthinee
    Tunakhun, Paweena
    Ngernpimai, Sawinee
    Srichaiyapol, Oranee
    Boonsiri, Patcharee
    Tippayawat, Patcharaporn
    Techasen, Anchalee
    Maraming, Pornsuda
    Choowongkomon, Kiattawee
    Daduang, Sakda
    Promdee, Limthong
    Daduang, Jureerut
    ANALYTICAL METHODS, 2024, 16 (26) : 4387 - 4394
  • [4] A novel handheld fluorescent microarray reader for point-of-care diagnostic
    Kozma, P.
    Lehmann, A.
    Wunderlich, K.
    Michel, D.
    Schumacher, S.
    Ehrentreich-Foerster, E.
    Bier, F. F.
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 415 - 420
  • [5] Point-of-care testing for HIV
    Dalcin, Daniel
    Bogoch, Isaac I.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2018, 190 (18) : E569 - E569
  • [6] HIV infection: Point-of-care testing
    Donovan, BJ
    Rublein, JC
    Leone, PA
    Pilcher, CD
    ANNALS OF PHARMACOTHERAPY, 2004, 38 (04) : 670 - 676
  • [7] HIV point-of-care testing pitfalls
    Chan, S. Y.
    Wyld, C.
    Rice, P.
    Lau, R.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2011, 22 (12) : 764 - 765
  • [8] Versatile and Sensitive Microfluidic Immunoassay for Improved Point-of-Care Diagnostics
    Bennett, S. J.
    Link, J. S.
    Dolence, A.
    Call, Z. D.
    Martinez, B.
    Henry, C. S.
    CLINICAL CHEMISTRY, 2024, 70 : I133 - I133
  • [9] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [10] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    Biosensors and Bioelectronics, 2021, 168