Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization

被引:1
|
作者
Ayoub Kounnoun
Mohamed EL Maadoudi
Francesco Cacciola
Luigi Mondello
Hajar Bougtaib
Naoual Alahlah
Nadia Amajoud
Aicha EL Baaboua
Adnane Louajri
机构
[1] Abd Al Malek Essaadi University,Laboratory of Applied Biology and Pathology, Department of Biology, Faculty of Sciences of Tetouan
[2] National Office of Food Safety ONSSA,Regional Analysis and Research Laboratory
[3] University of Messina,Department of Biomedical, Dental, Morphological and Functional Imaging Sciences
[4] University of Messina,Department of Chemical Biological, Pharmaceutical and Environmental Sciences
[5] University of Messina,Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
[6] University Campus Bio-Medico of Rome,Department of Sciences and Technologies for Human and Environment
[7] University of Messina,BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
来源
Chromatographia | 2020年 / 83卷
关键词
Histamine; Fish; HPLC-FLD; Pre-column derivatization; Optimization; Validation;
D O I
暂无
中图分类号
学科分类号
摘要
Histamine level determination in fish and fish products is important for human safety, fish quality and food industry. For this reason, a rapid, robust, and precise method is needed. To achieve this objective, an HPLC method with fluorescence detection was developed and validated. Histamine in fish samples was efficiently extracted with perchloric acid, and purified with ion-exchange solid-phase extraction cartridge. A pre-column derivatization was adopted with ortho-phthalaldehyde (OPA) in the presence of the reducing agent 2-mercaptoethanol, and the stability of the histamine-OPA derivatives was achieved with the acidification of the reaction medium. In terms of validation, besides the excellent linear correlations, satisfactory recoveries at all spiking levels ranging between 0 and 200 mg kg−1 were attained, with limit of detection calculated at 1.8 mg kg−1, whereas limit of quantification determined at 5 mg kg−1. The proposed method was successfully used in the analysis of reference materials and proficiency tests, and was found to be suitable, accurate, and rapid for detection and quantification of histamine in various fish samples.
引用
收藏
页码:893 / 901
页数:8
相关论文
共 50 条
  • [41] Determination of 1-deoxynojirimycin in Morus alba L. leaves using reversed-phase high performance liquid chromatography fluorescence detection with pre-column derivatization
    Xie Huiming
    Wu Fangrui
    Yang Yi
    Liu Jie
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (05) : 634 - 636
  • [42] Development of a pre-column derivatization ultra-high-performance liquid chromatography method for polysaccharide and monosaccharide quantification in Lycium barbarum
    Zhao, Zhilong
    Bai, Yunfeng
    Chen, Huan
    Wang, Weibiao
    Ding, Shuqin
    Zhang, Yue
    Sa, Yuping
    Chen, Guoning
    Ma, Xueqin
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (17)
  • [43] Determination of Biogenic Amines in Fish Meat and Fermented Foods Using Column-Switching High-Performance Liquid Chromatography with Fluorescence Detection
    Ishimaru, Mami
    Muto, Yuma
    Nakayama, Akari
    Hatate, Hideo
    Tanaka, Ryusuke
    FOOD ANALYTICAL METHODS, 2019, 12 (01) : 166 - 175
  • [44] Determination of 20 Free Amino Acids in Asparagus Tin by High-Performance Liquid Chromatographic Method after Pre-Column Derivatization
    Li, Weihua
    Hou, Meijun
    Cao, Yongsong
    Song, Huan
    Shi, Tianyu
    Gao, Xiwu
    Wang, Daning
    FOOD ANALYTICAL METHODS, 2012, 5 (01) : 62 - 68
  • [45] Determination of 20 Free Amino Acids in Asparagus Tin by High-Performance Liquid Chromatographic Method after Pre-Column Derivatization
    Weihua Li
    Meijun Hou
    Yongsong Cao
    Huan Song
    Tianyu Shi
    Xiwu Gao
    Daning Wang
    Food Analytical Methods, 2012, 5 : 62 - 68
  • [46] Validation of standard method EN ISO 19343 for the detection and quantification of histamine in fish and fishery products using high-performance liquid chromatography
    Duflos, Guillaume
    Inglebert, Gaelle
    Himber, Charlotte
    Degremont, Sylvie
    Lombard, Bertrand
    Brisabois, Anne
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2019, 288 : 97 - 101
  • [47] Determination of Histamine in Microdialysis Samples from Guinea Pig Skin by High-Performance Liquid Chromatography with Fluorescence Detection
    Yoshitake, T.
    Ijiri, S.
    Yoshitake, S.
    Todoroki, K.
    Yoshida, H.
    Kehr, J.
    Nohta, H.
    Yamaguchi, M.
    SKIN PHARMACOLOGY AND PHYSIOLOGY, 2012, 25 (02) : 65 - 72
  • [48] Development and validation of LC methods with visible detection using pre-column derivatization and mass detection for the assay of voglibose
    Raman, Nanduri V. V. S. S.
    Reddy, Kura Ratnakar
    Prasad, Adapa V. S. S.
    Ramakrishna, Karipeddi
    TALANTA, 2009, 77 (05) : 1869 - 1872
  • [49] Determination of alliin and its related substances in garlic using pre-column derivatization and reversed-phase high performance liquid chromatography
    Yuan Yaozuo
    Hang Taijun
    Ji Yu
    Zhang Zhengxing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (02) : 242 - 245
  • [50] Determination of Fluoxetine in Blood Samples by High-Performance Liquid Chromatography Using Derivatization Reagent
    Wozniakiewicz, M.
    Kuczara, J.
    Koscielniak, P.
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 667 - 677