Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography

被引:0
|
作者
R. Olszewski
L. Frison
M. Wisniewski
J. M. Denis
S. Vynckier
G. Cosnard
F. Zech
H. Reychler
机构
[1] Université Catholique de Louvain,Department of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc
[2] CH Lapeyronie,Department of Maxillofacial Surgery
[3] Medical University of Warsaw,Department of Oral and Maxillofacial Surgery
[4] Université Catholique de Louvain,Department of Oncology and Radiotherapy, Cliniques Universitaires Saint Luc
[5] Université Catholique de Louvain,Department of Medical Imaging, Cliniques Universitaires Saint Luc
[6] Université Catholique de Louvain,Department of Internal Medicine, Cliniques Universitaires Saint Luc
[7] Université Catholique de Louvain,Department of Oral and Maxillofacial Surgery, Oral and Maxillofacial Surgery Research Lab, Cliniques Universitaires Saint Luc
来源
Clinical Oral Investigations | 2013年 / 17卷
关键词
Cone-beam computed tomography; Three-dimensional imaging; Cephalometry; Dosimetry; Maxillofacial;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:285 / 292
页数:7
相关论文
共 50 条
  • [1] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    Olszewski, R.
    Frison, L.
    Wisniewski, M.
    Denis, J. M.
    Vynckier, S.
    Cosnard, G.
    Zech, F.
    Reychler, H.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 285 - 292
  • [2] Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review
    Sam, Alycia
    Currie, Kris
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel
    ANGLE ORTHODONTIST, 2019, 89 (02) : 317 - 332
  • [3] Cone-Beam Computed Tomography-Based Three-Dimensional McNamara Cephalometric Analysis
    Goncalves dos Santos, Rodrigo Mologni
    De Martino, Jose Mario
    Haiter Neto, Francisco
    Passeri, Luis Augusto
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : 895 - 899
  • [4] Development and Validation of Novel Three-Dimensional Craniofacial Landmarks on Cone-Beam Computed Tomography Scans
    Liberton, Denise K.
    Verma, Payal
    Contratto, Anthony
    Lee, Janice S.
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (07) : E611 - E615
  • [5] Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses
    Olszewski, Raphael
    Tanesy, Olivier
    Cosnard, Guy
    Zech, Francis
    Reychler, Herve
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (03) : 214 - 221
  • [6] Reproducibility of three-dimensional posterior cranial base angles using low-dose computed tomography
    Olszewski, R.
    Frison, L.
    Schoenarts, N.
    Khonsari, R. H.
    Odri, G. A.
    Zech, F.
    Reychler, H.
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2407 - 2414
  • [7] Prostatic artery embolization using three-dimensional cone-beam computed tomography
    Cadour, F.
    Tradi, F.
    Habert, P.
    Scemama, U.
    Vidal, V.
    Jacquier, A.
    Bartoli, J-M
    Moulin, G.
    Bessayah, A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (11) : 721 - 725
  • [8] Reproducibility of three-dimensional posterior cranial base angles using low-dose computed tomography
    R Olszewski
    L Frison
    N Schoenarts
    RH Khonsari
    GA Odri
    F Zech
    H Reychler
    Clinical Oral Investigations, 2017, 21 : 2407 - 2414
  • [9] Reliability and reproducibility of three-dimensional cephalometric landmarks using CBCT: a systematic review
    Lisboa, Cinthia de Oliveira
    Masterson, Daniele
    Jardim da Motta, Andrea Fonseca
    Motta, Alexandre Trindade
    JOURNAL OF APPLIED ORAL SCIENCE, 2015, 23 (02) : 112 - 119
  • [10] Evaluating the precision and reproducibility of cephalometric landmarks in locally reconstructed lateral cephalometric radiographs from cone beam computed tomography (CBCT)
    Chuan Cai
    Hongkun Li
    Haodong Zhang
    Na Huo
    Jing Wang
    Tianqi Li
    Nuo Xu
    Tong Zhang
    BMC Oral Health, 25 (1)