Application of high temperature heat pipe in hypersonic vehicles thermal protection

被引:0
|
作者
Tong Bai
Hong Zhang
Hui Xu
机构
[1] Nanjing University of Technology,College of Energy
关键词
thermal protection; high temperature heat pipe; heat transfer limit; start-up time;
D O I
暂无
中图分类号
学科分类号
摘要
In order to develop further the application of high temperature heat pipe in hypersonic vehicles thermal protection, the principles and characteristics of high temperature heat pipe used in hypersonic vehicles thermal protection were introduced. The methods of numerical simulation, theory analysis and experiment research were utilized to analyze the frozen start-up and steady state characteristic of the heat pipe as well as the machining improvement for fabricating irregularly shaped heat pipe which is suitable for leading edge of hypersonic vehicles. The results indicate that the frozen start-up time of heat pipe is long (10 min) and there exists large temperature difference along the heat pipe (47 °C/cm), but the heat pipe can reduce the temperature in stagnation area of hypersonic vehicles from 1 926 to 982 °C and work normally during 1 000–1 200°C. How to improve the maximum heat transfer capability and reduce the time needed for start-up from frozen state of the heat pipe by optimizing thermostructure such as designing of a novel wick with high performance is the key point in hypersonic vehicles thermal protection of heat pipe.
引用
收藏
页码:1278 / 1284
页数:6
相关论文
共 50 条
  • [41] Assessment of the Aerodisk Size on Drag Reduction and Thermal Protection of High-Bluntness Vehicles at Hypersonic Speeds
    Kharati-Koopaee, Masoud
    Gazor, Hesam
    JOURNAL OF AEROSPACE ENGINEERING, 2017, 30 (04)
  • [42] Thermal numerical model of a high temperature heat pipe heat exchanger under radiation
    Jung, Eui Guk
    Boo, Joon Hong
    APPLIED ENERGY, 2014, 135 : 586 - 596
  • [43] Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions
    Zhang, Jiarui
    Guo, Kailun
    Liu, Lining
    Meng, Xue
    Wang, Chenglong
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    Chong, Chen
    ANNALS OF NUCLEAR ENERGY, 2025, 212
  • [44] Mechanism of thermomechanical coupling of high temperature heat pipe cooled C/C composite material thermal protection structure
    Liu, Donghuan
    Zheng, Xiaoping
    Wang, Fei
    Liu, Yinghua
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2010, 27 (03): : 43 - 49
  • [45] Validation of heat transfer models and optimization of heat shielding performance of high-temperature multilayer insulations for hypersonic vehicles
    Wang, Kuan
    Li, Jiangtao
    Hu, Xiaoxia
    Yang, Shuo
    Zhang, Chensi
    Guo, Anran
    Du, Haiyan
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [46] Experimental demonstration of a new concept of drag reduction and thermal protection for hypersonic vehicles
    Zonglin Jiang Yunfeng Liu Guilai Han Wei Zhao Key Laboratory of High Temperature Gas Dynamics
    Acta Mechanica Sinica, 2009, (03) : 417 - 419
  • [47] Experimental demonstration of a new concept of drag reduction and thermal protection for hypersonic vehicles
    Jiang, Zonglin
    Liu, Yunfeng
    Han, Guilai
    Zhao, Wei
    ACTA MECHANICA SINICA, 2009, 25 (03) : 417 - 419
  • [48] Wireless subsurface microsensors for health monitoring of thermal protection systems on hypersonic vehicles
    Milos, FS
    Watters, DG
    Pallix, JB
    Bahr, AJ
    Huestis, DL
    ADVANCED NONDESTRUCTIVE EVALUATION FOR STRUCTURAL AND BIOLOGICAL HEALTH MONITORING, 2001, 4335 : 74 - 82
  • [49] Experimental demonstration of a new concept of drag reduction and thermal protection for hypersonic vehicles
    Zonglin Jiang Yunfeng Liu Guilai Han Wei Zhao Key Laboratory of High Temperature Gas Dynamics Institute of Mechanics Chinese Academy of Sciences Beijing China
    Acta Mechanica Sinica, 2009, 25 (03) : 417 - 419
  • [50] Active flow control by a novel combinational active thermal protection for hypersonic vehicles
    Huang, Jie
    Yao, Wei-Xing
    ACTA ASTRONAUTICA, 2020, 170 : 320 - 330