Computer-Aided Detection of Intracranial Aneurysms in MR Angiography

被引:0
|
作者
Xiaojiang Yang
Daniel J. Blezek
Lionel T. E. Cheng
William J. Ryan
David F. Kallmes
Bradley J. Erickson
机构
[1] Mayo Clinic,
[2] Medical Imaging Informatics Innovation Center,undefined
[3] Mayo Clinic,undefined
[4] Department of Radiology,undefined
[5] Mayo Clinic,undefined
[6] College of Medicine,undefined
来源
Journal of Digital Imaging | 2011年 / 24卷
关键词
Computer-aided detection (CAD); magnetic resonance angiography (MRA); intracranial aneurysm; aneurysm detection;
D O I
暂无
中图分类号
学科分类号
摘要
Intracranial aneurysms represent a significant cause of morbidity and mortality. While the risk factors for aneurysm formation are known, the detection of aneurysms remains challenging. Magnetic resonance angiography (MRA) has recently emerged as a useful non-invasive method for aneurysm detection. However, even for experienced neuroradiologists, the sensitivity to small (<5 mm) aneurysms in MRA images is poor, on the order of 30~60% in recent, large series. We describe a fully automated computer-aided detection (CAD) scheme for detecting aneurysms on 3D time-of-flight (TOF) MRA images. The scheme locates points of interest (POIs) on individual MRA datasets by combining two complementary techniques. The first technique segments the intracranial arteries automatically and finds POIs from the segmented vessels. The second technique identifies POIs directly from the raw, unsegmented image dataset. This latter technique is useful in cases of incomplete segmentation. Following a series of feature calculations, a small fraction of POIs are retained as candidate aneurysms from the collected POIs according to predetermined rules. The CAD scheme was evaluated on 287 datasets containing 147 aneurysms that were verified with digital subtraction angiography, the accepted standard of reference for aneurysm detection. For two different operating points, the CAD scheme achieved a sensitivity of 80% (71% for aneurysms less than 5 mm) with three mean false positives per case, and 95% (91% for aneurysms less than 5 mm) with nine mean false positives per case. In conclusion, the CAD scheme showed good accuracy and may have application in improving the sensitivity of aneurysm detection on MR images.
引用
收藏
页码:86 / 95
页数:9
相关论文
共 50 条
  • [21] Volume-rendered TOF MR angiography: detection and characterization of intracranial aneurysms
    Mallouhi, A
    Felber, S
    Chemelli, A
    Dessl, A
    Auer, A
    Schocke, M
    Jaschke, WR
    Waldenberger, P
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1041 - 1041
  • [22] Computer-aided diagnosis scheme for detection of lacunar infarcts on MR images
    Uchiyama, Yoshikazu
    Yokoyama, Ryujiro
    Ando, Hiromich
    Asano, Takahiko
    Kato, Hiroki
    Yamakawa, Hiroyasu
    Yamakawa, Haruki
    Hara, Takeshi
    Iwama, Toru
    Hoshi, Hiroaki
    Fujita, Hiroshi
    ACADEMIC RADIOLOGY, 2007, 14 (12) : 1554 - 1561
  • [23] Computer-aided Tumor Detection System Using Brain MR Images
    Ari, Ali
    Alpaslan, Nuh
    Hanbay, Davut
    2015 MEDICAL TECHNOLOGIES NATIONAL CONFERENCE (TIPTEKNO), 2015,
  • [24] INTRACRANIAL ANEURYSMS AND MR-ANGIOGRAPHY - QUESTIONS AND ANSWERS
    WINN, HR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1617 - 1617
  • [25] Value of CT and MR angiography for diagnostics of intracranial aneurysms
    Roth, C.
    RADIOLOGE, 2011, 51 (02): : 106 - 112
  • [26] Computer-aided detection in mammography
    Astley, SM
    Gilbert, FJ
    CLINICAL RADIOLOGY, 2004, 59 (05) : 390 - 399
  • [27] Intracranial aneurysms: CT angiography and MR angiography for detection - Prospective blinded comparison in a large patient cohort
    White, PM
    Teasdale, EM
    Wardlaw, JM
    Easton, V
    RADIOLOGY, 2001, 219 (03) : 739 - 749
  • [29] Computer-aided detection is here: will computer-aided quality algorithms soon follow?
    McGill, Sarah K.
    ENDOSCOPY, 2022, 54 (08) : 769 - 770
  • [30] Automated computer-aided stenosis detection at coronary CT angiography: initial experience
    Arnoldi, Elisabeth
    Gebregziabher, Mulugeta
    Schoepf, U. Joseph
    Goldenberg, Roman
    Ramos-Duran, Luis
    Zwerner, Peter L.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Thilo, Christian
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1160 - 1167